Registration Dossier

Administrative data

Endpoint:
appearance / physical state / colour
Type of information:
experimental study
Adequacy of study:
key study
Study period:
13 November 2009 to 4 December 2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted to GLP in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report Date:
2010

Materials and methods

Test guideline
Qualifier:
no guideline required
Principles of method if other than guideline:
The appearance, physical state and colour was assessed via a visual inspection at the testing laboratory.
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Physical state at 20°C and 1013 hPa:
solid
Form / colour / odour
Form:
powder
Colour:
light brown
Odour:
slight
Substance type:
organic

Applicant's summary and conclusion

Conclusions:
The test material has been determined to be a light brown solid powder.
Executive summary:

In a physico-chemical properties study (0656/0410), the test material was determined to be a light brown solid powder.