Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Deviations:
no
Principles of method if other than guideline:
The sample was fractionated by 100 μm sieve and tested by scanning electron microscopy (SEM: Philips XL 30 FEG). The fraction < 100 μm was gushed to carbon pads and sputtered with gold.
GLP compliance:
no
Type of method:
sieving
Remarks:
The sample was fractionated by 100 μm sieve and tested by scanning electron microscopy (SEM: Philips XL 30 FEG). The fraction < 100 μm was gushed to carbon pads and sputtered with gold.
Percentile:
D50
Mean:
51 µm
Remarks on result:
other: spherical volume
Percentile:
D50
Mean:
47 µm
Remarks on result:
other: Cubical Volume

Sieve Fraction:

weighted sample: 2.1387 g

weight fraction <100 μm: 0.1030 g

mass fraction <100 μm: 4.82%

Particle Size Distribution (Sieve Fraction < 100 μm)

Result: Mass Fraction (calculated)

Particle Size

Spherical Volume

Cubical Volume

< 4 μm

0.006%

0.007%

4-10 μm

0.63%

0.56%

10-100 μm

94.35%

96.84%

> 100 μm

5.01%

2.59%

Median (diameter)

51 μm

47 μm

Conclusion:

All particles with a mean diameter less than 100 μm have a mass fraction of 4.82%. 0.006% spherical and 0.007% cubical volume of this mass fraction has a mean diameter less than 4 μm.

Conclusions:
The particle size distribustion was determined according to OECD TG 110. Mass fraction is calculated for spherical and cubical volume in classes of particle diameters <4 μm, 4-10 μm, 10-100 μm and > 100 μm.
The D50 was determined to be 51 µm (spherical volume) and 47 µm (cubical volume), respectively.
All particles with a mean diameter less than 100 μm have a mass fraction of 4.82%. 0.006% spherical and 0.007% cubical volume of this mass fraction has a mean diameter less than 4 μm.

Description of key information

The particle size distribustion was determined according to OECD TG 110. Mass fraction is calculated for spherical and cubical volume in classes of particle diameters <4 μm, 4-10 μm, 10-100 μm and > 100 μm.

The D50 was determined to be 51 µm (spherical volume) and 47 µm (cubical volume), respectively. All particles with a mean diameter less than 100 μm have a mass fraction of 4.82%. 0.006% spherical and 0.007% cubical volume of this mass fraction has a mean diameter less than 4 μm.

Additional information