Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
Not reported
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Study conducted in accordance with generally accepted scientific principles, possibly with incomplete reporting or methodological deficiencies, which do not affect the quality of the relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
Particle size analysis was performed using light obscuration. Analysis of a dust sample was performed using a Particle Sizing System Accusizer 780 equipped with an LE400-0.5 sensor.
GLP compliance:
not specified
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
5-ethoxy-2-({5-ethoxy-7-fluoro-[1,2,4]triazolo[1,5-c]pyrimidin-2-yl}disulfanyl)-7-fluoro-[1,2,4]triazolo[1,5-c]pyrimidine
EC Number:
695-187-4
Cas Number:
166524-75-0
Molecular formula:
C14H12F2N8O2S2
IUPAC Name:
5-ethoxy-2-({5-ethoxy-7-fluoro-[1,2,4]triazolo[1,5-c]pyrimidin-2-yl}disulfanyl)-7-fluoro-[1,2,4]triazolo[1,5-c]pyrimidine
Test material form:
other: dust
Details on test material:
- Name of test material (as cited in study report): DEDS
- Physical state: solid

Results and discussion

Particle size
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.

Any other information on results incl. tables

Table 1 Weight Fraction Analysis

Run

Weight % <63 µm (from sieve and Accusizer Analysis)

Weight % <250 µm (from sieve analysis)

Weight % 250 to 425 µm (from sieve analysis)

Weight % >425 µm (from sieve analysis)

1

15.9

96.5

3.5

0.0

2

12.4

3

17.6

Average

15.3

 

Table 2 Accusizer Data

The data reported in Table 2 has been normalised to account for the fact that the sample contained material above 250 µm.

<250 µm Sieve Portion - Run 1

Diameter (microns)

Particle Count

Volume

(%)

Cumulative Volume

(%)

Normalised Volume

(%)

Normalised Cumulative Volume (%)

0.97258

34125

0.005

0.005

0.005

0.005

1.07741

36504

0.007

0.012

0.007

0.012

1.19353

37909

0.01

0.022

0.010

0.021

1.32218

37196

0.013

0.035

0.013

0.034

1.46468

37380

0.017

0.052

0.016

0.050

1.62255

36573

0.023

0.075

0.022

0.072

1.79744

32897

0.028

0.103

0.027

0.099

1.99117

29080

0.034

0.137

0.033

0.132

2.20578

25465

0.04

0.177

0.039

0.171

2.44353

22234

0.048

0.225

0.046

0.217

2.7069

19952

0.058

0.283

0.056

0.273

2.99965

18667

0.074

0.357

0.071

0.344

3.32186

17314

0.094

0.451

0.091

0.435

3.67989

16427

0.121

0.572

0.117

0.551

4.07652

15523

0.155

0.727

0.149

0.701

4.5159

15087

0.205

0.932

0.198

0.898

5.00264

14795

0.273

1.205

0.263

1.162

5.54183

14355

0.36

1.565

0.347

1.509

6.13915

13198

0.451

2.016

0.435

1.943

6.80084

16622

0.539

2.555

0.520

2.463

7.53386

10068

0.635

3.19

0.612

3.075

8.34588

8132

0.697

3.887

0.672

3.747

9.24542

6226

0.726

4.613

0.700

4.447

10.24191

4285

0.679

5.292

0.655

5.101

11.34581

2849

0.614

5.906

0.592

5.693

12.5687

1760

0.516

6.422

0.497

6.191

13.92338

1009

0.402

6.824

0.388

6.578

15.42408

616

0.333

7.157

0.321

6.899

17.08653

389

0.286

7.443

0.276

7.175

18.92817

218

0.218

7.661

0.210

7.385

20.9683

118

0.161

7.822

0.155

7.540

23.22832

106

0.196

8.018

0.189

7.729

25.73192

68

0.171

8.189

0.165

7.894

28.50538

45

0.154

8.343

0.148

8.043

31.57777

51

0.237

8.58

0.228

8.271

34.9813

43

0.272

8.852

0.262

8.533

38.75168

35

0.301

9.153

0.290

8.823

42.92844

45

0.525

9.678

0.506

9.330

47.55539

54

0.857

10.535

0.826

10.156

52.68104

65

1.402

11.937

1.352

11.507

58.35914

75

2.199

14.136

2.120

13.627

64.64924

79

3.149

17.285

3.036

16.663

71.61731

73

3.956

21.241

3.814

20.476

79.33642

91

6.705

27.946

6.464

26.940

87.88751

70

7.011

34.957

6.759

33.699

97.36028

70

9.531

44.488

9.188

42.886

107.8541

40

7.404

51.892

7.137

50.024

119.4788

48

12.079

63.971

11.644

61.668

132.3566

37

12.568

76.629

12.202

73.870

146.6223

21

9.766

86.395

9.414

83.285

162.4257

12

7.587

93.982

7.314

90.599

179.9324

7

6.016

99.998

5.799

96.398

199.326

0

0

99.998

0.000

96.398

220.8099

0

0

99.998

0.000

96.398

244.6093

0

0

99.998

0.000

96.398

270.974

0

0

99.998

0.000

96.398

300.1803

0

0

99.998

0.000

96.398

330.4139

0

0

99.998

0.000

96.398

Applicant's summary and conclusion

Conclusions:
Weight fraction analysis of the ‘as received’ test material resulted in a weight % <63 µm (from sieve and Accusizer Analysis) of 15.3 %. The following values were obtained from sieve analysis only: weight % <250 µm was 96.5; weight % 250 to 425 µm was 3.5; weight % >425 µm was 0.0.
Executive summary:

Particle size analysis was performed using light obscuration. Analysis of the test material was performed using a Particle Sizing System Accusizer 780 equipped with an LE400-0.5 sensor.

The 'as received' samples were sieved using a 425 µm sieve in order to determine the weight percent less than 425 µm. An additional sieve analysis was performed to remove particles greater than 250 µm and the less than 250 µm portion of the sample was analysed using the Accusizer particle size analyser.

The Accusizer data was combined with the sieve analyses to obtain the weight percent of the samples less than 63 µm and the size distribution of those particles less than 63 µm.

 

Weight fraction analysis of the ‘as received’ sample resulted in a weight % <63 µm (from sieve and Accusizer Analysis) of 15.3 %. The following values were obtained from sieve analysis only: weight % <250 µm was 96.5; weight % 250 to 425 µm was 3.5; weight % >425 µm was 0.0.