Registration Dossier

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Acceptable, well documented study report which meets basic scientific principles

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
the melting point was determined by differential thermal analysis.
GLP compliance:
no
Type of method:
thermal analysis
Remarks:
Differential Scanning Calorimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Melting / freezing point
Melting / freezing pt.:
135 °C
Atm. press.:
1 013 hPa

Any other information on results incl. tables

The DSC results of two measurements:

Thermal signal range (°C):

1st measurement:

Peak: 134.91 °C

Endo: 125 - 147.135; Engergy (kJ/kg): -139

Exo: 193 - 374.207; Engergy (kJ/kg): 546

2nd measurement:

Peak: 135.37 °C

Endo: 124 - 149.135; Engery (kJ/kg): - 130

Exo: 194 - 329.329; Engery (kJ/kg): 402

Applicant's summary and conclusion