Registration Dossier

Physical & Chemical properties

Additional physico-chemical information

Administrative data

Endpoint:
additional physico-chemical information
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report Date:
2013

Materials and methods

Principles of method if other than guideline:
The SADT of test substance was determined by using methodology H.4 (using Dewar flasks) in accordance with the Recommendations on the Transport of Dangerous Goods.
GLP compliance:
no
Endpoint investigated:
other: self-reactive

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Results:
The substance has not to be classified in the Division 4.1 - self-reactive substances.
SADT50L > 75 °C

Any other information on results incl. tables

Volume of the Dewar flask [mL]

Cooling time[hours]

Heat losses

[mW·kg-1·K-1]

Dewar used at a temperature of

[°C]

500

18

45

75

 

The heat loss determined is in the range for solids indicated in the Recommendations on the Transport of Dangerous Goods for a drum of 50 L.

The maximal temperature rise in the centre of the sample after reaching the oven-temperature is below 1 K thus not reaching the test criterion value of 6 K.