Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
18 January 2011 to 01 June 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Auto-ignition temperature:
> 400 °C
Atm. press.:
1 027 mBar
Remarks on result:
other: Rikabinol HB was determined not to auto-ignite below 400°C.
Conclusions:
Rikabinol HB was determined not to auto-ignite below 400°C.

Description of key information

Rikabinol HB was determined not to auto-ignite below 400°C.

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
400 °C

Additional information

The auto-ignition temperature of HBPA was determined using the method described in BS 4056 (Huntingdon Life Sciences, 2012, Study MOG0004). The test was carried out using a procedure designed to be compatible with EC Method A.15. The test was conducted in compliance with GLP.

HBPA was determined not to auto-ignite below 400°C.