Registration Dossier

Administrative data

Endpoint:
density
Remarks:
density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: see guideline deviations below

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report Date:
2013

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
yes
Remarks:
no constant temperature guaranteed (old equipment: Micromeritics Accupyc 1330: gaspycnometrie (helium)) + temperature above 20°C possible (although of less influence on densities of solids vs liquids) + no duplicate measures
Principles of method if other than guideline:
Guideline deviations: no constant temperature guaranteed (old equipment: Micromeritics Accupyc 1330: gaspycnometrie (helium)) + temperature above 20°C possible (although of less influence on densities of solids vs liquids) + no duplicate measures
GLP compliance:
no
Type of method:
pycnometer method

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Density
Type:
density
Density:
1.32 other: g/ml
Remarks on result:
other: Deviations from 20°C are possible (see guideline deviations above).

Applicant's summary and conclusion