Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Deviations:
no
GLP compliance:
yes
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
cascade impaction
Type of particle tested:
agglomerate
Type of distribution:
volumetric distribution
Mass median aerodynamic diameter:
3.09 µm
Geometric standard deviation:
2.65
Key result
Percentile:
D10
Mean:
> 0.32 - < 0.83 µm
St. dev.:
0
Remarks on result:
other: st dev was set to 0, based on no data
Key result
Percentile:
D25
Mean:
ca. 4.4 µm
St. dev.:
0
Remarks on result:
other: st dev was set to 0, based on no data
Conclusions:
The particle size distribution was determined in the the context of the study for acute inhalation.

Description of key information