Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 244-870-1 | CAS number: 22252-43-3
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Toxicity to microorganisms
Administrative data
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 15 January 2010
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: This study has been performed according to OECD and/or EC guidelines and according tot GLP principles
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 010
- Report date:
- 2010
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method C.11 (Biodegradation: Activated Sludge Respiration Inhibition Test)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- ISO 8192 (Water quality - Test for inhibition of oxygen consumption by activated sludge for carbonaceous and ammonium oxidation)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
Test material
- Reference substance name:
- (6R-trans)-7-amino-3-methyl-8-oxo-5-thia-1-azabicyclo[4.2.0]oct-2-ene-2-carboxylic acid
- EC Number:
- 244-870-1
- EC Name:
- (6R-trans)-7-amino-3-methyl-8-oxo-5-thia-1-azabicyclo[4.2.0]oct-2-ene-2-carboxylic acid
- Cas Number:
- 22252-43-3
- Molecular formula:
- C8H10N2O3S
- IUPAC Name:
- 7-amino-3-methyl-8-oxo-5-thia-1-azabicyclo[4.2.0]oct-2-ene-2-carboxylic acid
- Details on test material:
- - Name of test material (as cited in study report): 7-ADCA
- Substance type: White powder
- Physical state: Solid
- Analytical purity: 99.0%
- Lot/batch No.: D212013
- Expiration date of the lot/batch: 28 February 2011 (retest date)
- Stability under storage conditions: Stable
- Storage condition of test material: In refrigerator (2-8°C) in the dark
- Stability in water Not indicated
- Solubility in water 0.1% (20°C)
Constituent 1
Sampling and analysis
- Analytical monitoring:
- no
Test solutions
- Vehicle:
- no
- Details on test solutions:
- Since 7-ADCA was hardly soluble in water test concentrations were prepared separately in
Milli-RO water (tap water purified by reverse osmosis; Millipore Corp., Bedford, Mass., USA).
Two 1 litre test bottles were filled with 250 ml of test substance mixtures with initial loading rates of 200 mg/l. These mixtures were treated with ultrasonic waves for 5 minutes and stirred in closed brown glass bottles for 24 hours. Subsequently, 16 ml synthetic sewage feed, 200 ml sludge and Milli-RO water up to 500 ml were added resulting in a loading rate of 100 mg/l . This loading rate was tested in duplicate. Optimal contact between the test substance and test organisms was ensured applying continuous aeration and stirring during the 3 hour exposure period.
Test organisms
- Test organisms (species):
- activated sludge of a predominantly domestic sewage
- Details on inoculum:
- The sludge was coarsely sieved, washed and diluted with ISO-medium. A small amount of the sludge was weighed and dried overnight at ca. 105°C to determine the amount of suspended solids (4.2 g/l of sludge, as used for the test). The pH was 7.8 on the day of testing. The batch of sludge was used one day after collection; therefore 50 ml of synthetic sewage feed was added per litre of activated sludge at the end of the collection day. The sludge was kept aerated at test temperature until use.
Study design
- Test type:
- static
- Water media type:
- freshwater
- Limit test:
- yes
- Total exposure duration:
- 3 h
- Post exposure observation period:
- Oxygen consumption was measured and recorded for approximately 10 minutes after the 3 hours exposure period.
Test conditions
- Test temperature:
- between 18.9 and 19.5°C.
- pH:
- 7.9 - 8.0
- Dissolved oxygen:
- Oxygen consumption:
Controls for 7-ADCA:60-62 mg O2/l/h
7-ADCA:59-60 mg O2/l/h
The oxygen concentration at the start of the measurements was at least 6.5 mg O2/l - Nominal and measured concentrations:
- Loading rate at 100 mg/l
- Details on test conditions:
- TEST SYSTEM
- Type (delete if not applicable): open
- Material, size, headspace, fill volume:All glass, approximately 300 ml oxygen bottles and 1 litre test bottles.
- Aeration:During exposure with clean, oil free air
- No. of vessels per concentration (replicates):2
- No. of vessels per control (replicates):2
- Biomass loading rate: 1.7 g/l suspended solids in the final mixture
TEST MEDIUM / WATER PARAMETERS
- Source/preparation of dilution water:Tap-water purified by reverse osmosis (Milli-RO)
EFFECT PARAMETERS MEASURED (with observation intervals if applicable) :
The respiration rate from each vessel, in mg O2/l/hr, was calculated from the linear part of the respiration curve, which was generally between 2.5 and 6.5 mg O2/l.
TEST CONCENTRATIONS
limt at a loading rate of 100 mg/l - Reference substance (positive control):
- yes
- Remarks:
- 3,5-dichlorophenol
Results and discussion
Effect concentrationsopen allclose all
- Duration:
- 3 h
- Dose descriptor:
- EC50
- Effect conc.:
- > 100 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Remarks:
- respiration rate
- Duration:
- 3 h
- Dose descriptor:
- NOEC
- Effect conc.:
- 100 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Remarks:
- respiration rate
- Details on results:
- No significant inhibition of respiration rate of the sludge was recorded at 100 mg 7-ADCA per litre. The duplicate measurement confirmed the result of the first measurement. Therefore, no further testing was needed. Hence, the EC50 of 7-ADCA exceeded a loading rate of 100 mg/l.
- Results with reference substance (positive control):
- The EC50 of 3,5-dichlorophenol was in the accepted range of 5-30 mg/l (11 mg/l)
- Reported statistics and error estimates:
- The percentage inhibition was plotted against the logarithm of the concentrations. The EC50 for the reference substance, was determined using linear regression analysis.
For 7-ADCA no EC50 could be calculated because the test substance proved to be non-toxic (EC50 > 100 mg/l).
Applicant's summary and conclusion
- Validity criteria fulfilled:
- yes
- Conclusions:
- Under the conditions of this present test, 7-ADCA was not toxic to waste water (activated sludge) bacteria at a loading rate of 100 mg/l (EC50 > a loading rate of 100 mg/l).
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.