Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
22/08/2014 – 09/10/2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Remarks on result:
other: Due to the sample boiling higher test temperatures could not be attained and therefore testing was terminated.
Remarks:
No flash point to Boiling therefore no flash point can be determined.

Full test results:

 Temperature (°C) Barometric Presure (kPa)  Igbition Yes (y) / No (n)  Halo/Enlarged test flame ?   Yes (y) / No (n) 
 20.8  102.0  n  n
 21 -30   102.0  n  n
 31 -40   102.0  n  n
 41 -50   102.0  n  n
 51 -60   102.0  n  n
 61 -70   102.0  n  n
 71 -80   102.0  n  n
 81 -90   102.0  n  n
 91 -100 102.0  n  n
 101 -110   102.0  n  n
 111 -120   102.0  n  n
 121 -130   102.0  n  n
 131 -140   102.0  n  n

 141 -150

  102.0  n  n
 151 -160   102.0 n  n
 161 -170   102.0  n  n
 171 -180   102.0  n  n
 181 -190   102.0  n  n
 191 -200   102.0  n  n
 201 -210   102.0  n  n
 211 -220   102.0  n  n
 221 -230   102.0  n  n
 231 -235*   102.0  n  n

* Due to the sample boiling higher test temperatures could not be attained and therefore testing was terminated.

Interpretation of results:
GHS criteria not met
Conclusions:
Due to the sample boiling higher test temperatures could not be attained and therefore testing was terminated. No flash point can be detremined.
No flash point to Boiling.

Description of key information

 Due to the sample boiling higher test temperatures could not be attained and therefore testing was terminated. No flash point can be detremined.