Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: see 'Remark'
Remarks:
According to appendix R7-1 of ECHA Guidance on Information Requirements and Chemical Safety Assessment multiple techniques should be applied to investigate phys. chem. properties of particulates, although different measurement methods may not provide comparable results. Laser diffraction is the well experienced standard procedure for pigments to determine particle size distribution of the pigment as it is manufactured and delivered.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: ISO 13320-1
Principles of method if other than guideline:
Particle size determination by laser diffraction (Malvern apparatus)
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
N-(4-chloro-2,5-dimethoxyphenyl)-2-[[2,5-dimethoxy-4-[(phenylamino)sulphonyl]phenyl]azo]-3-oxobutyramide
EC Number:
235-427-3
EC Name:
N-(4-chloro-2,5-dimethoxyphenyl)-2-[[2,5-dimethoxy-4-[(phenylamino)sulphonyl]phenyl]azo]-3-oxobutyramide
Cas Number:
12225-18-2
Molecular formula:
C26H27ClN4O8S
IUPAC Name:
N-(4-chloro-2,5-dimethoxyphenyl)-2-{[2,5-dimethoxy-4-(phenylsulfamoyl)phenyl]diazenyl}-3-oxobutanamide

Results and discussion

Particle sizeopen allclose all
Percentile:
D50
Mean:
9.8 µm
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D10
Mean:
0.88 µm
St. dev.:
0.05
Percentile:
D50
Mean:
9.8 µm
St. dev.:
1.3
Percentile:
D90
Mean:
227 µm
St. dev.:
63

Any other information on results incl. tables

For further percentiles see attached report.

Given standard deviation is based on the general experience with the method and pigments. The estimated values are typical standard deviations for pigments:

D10: 4% of D10 (minimum value 0,05 µm)

D50: 13% of D50 (minimum value 0,1 µm)

D90: 29% of D90 - D50

Applicant's summary and conclusion

Conclusions:
The mass median diameter is 9.8 µm.
Executive summary: