The particle size distribution (granulometry) of diiodohydroxyquinoline by the sieve analysis method was found to be in the range of 75 micrometer to 500 micrometer. Majority of the particles were found to be in the size of 250 micrometer (45.4%).

Additional information

Based on the principle of measurement of relative amounts of particles present, sorted according to size, sieve analysis method have been used in this case and the particle size distribution (granulometry) of diiodohydroxyquinoline was found to be in the range of 75 micrometer to 500 micrometer. Majority of the particles were found to be in the size range of 250 to 500 micrometer.