Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012-11-15 until 2013-01-07
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Guideline compliant study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report Date:
2013

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
GLP compliance:
not specified
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
other: liquid

Results and discussion

Flash point
Flash point:
61 °C
Atm. press.:
1 013 hPa

Applicant's summary and conclusion