Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

First aid general principles

Important information

In case of doubt or in the presence of symptoms contact a physician. In case of severe symptoms, call your local health care emergency number. Call a poison control center in order to receive toxicological advice for the clinical management of poisoning.

Inhalation

In the case of respiratory symptoms (cough, dyspnea) move the person to fresh air, place in a semi-seated position, and administer oxygen. Provide artificial respiration if the person is not breathing.

Skin contact

Flush the skin with copious amounts of water for at least 15 minutes. Consult a physician if there are symptoms of skin irritation and/or pain.

Eye contact

Remove contact lenses. Flush the eyes, kept open, with copious amounts of running water for at least 15 minutes. Consult a physician, especially if there are symptoms of eye irritation and/or pain.

Ingestion

Do not administer anything by mouth unless advised to do so by a poison control center. Do not induce emesis. Rinse the mouth and consult a physician

Fire-fighting measures

General information

Move all people away and stay upwind of the fire. Do not enter closed rooms without adequate protection.

Suitable extinguishing media

No special estinguishing media is advisable for this substance. Use the standard estinguishing media. In the choice of extinguishing media, consider the other materials involved in the fire.

Extinguishing media which shall not be used for safety reasons

None.

Exposure hazards arising from the substance itself, combustion products, resulting gases

In the case of fire, irritant or toxic fumes may develop from the substance and from the other materials involved in the fire.

Protective equipment for fire-fighters

No special equipment for this substance is needed. Use standard fire-fighters equipments.

Accidental release measures

Environmental precautions

In case of spills, do not allow the substance entering drains or water courses. Remove the substance and send it for correct disposal.

Personal precautions, protective equipment and emergency procedures

Use personal protective equipment.

Avoid breathing vapors, mist or gas. Ensure adequate ventilation.

Methods and materials for containment and cleaning up

Contain spillage, collect and place it in container for disposal according to local and national regulations.

Handling and storage

Take the necessary measures to avoid human and environmental exposure. Do not inhale vapours or fogs. Store in original containers or other appropriately labelled, suitable containers in an environment away from heat sources, drains and watercourses. Handling and storage may be done at environmental temperature and in a dry place.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
-
Shippingopen allclose all
Labels:
-
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
-
Shippingopen allclose all
Labels:
-
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
-
Shipping information
Proper shipping name and description:
-
Chemical name:
-
Labels:
-
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
-
Shipping information
Proper shipping name and description:
-
Chemical name:
-
Labels:
-
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

According to the Company internal procedures, the substance is used under strictly controlled condition (SCC) during its whole lifecycle:

(a) the substance is rigorously controlled from its arrival to its use and transformation;

(b) procedural (Standard Operating Procedures for use) and control technologies are used to minimize emission and any resulting exposure;

(c) the substance is handled only by trained and authorized personnel;

(d) in the case of cleaning and maintenance works, special procedures such as equipment washing are applied before the system is opened and entered;

(e) in cases of accident and where waste is generated, there is an Emergency Plan to minimize emissions and the resulting exposure;

(f) substance-handling procedures are well documented and strictly supervised by the site operator.

A periodic environmental monitoring confirms the efficacy of the above practices.

Details about SCC, exposure controls and personal protection are given in the "RMM_details" document which is attached in section 13 of the Registration Dossier.

Stability and reactivity

STABILITY: conditions to be avoided: sensitivity to oxidation

REACTIVITY: Chemical reaction with oxidising acids and basis

Disposal considerations

For disposal purposes, the substance is considered as special waste. If needed, contact a center authorized to dispose of this type of waste. Do not dispose of the product in the environment.

Disposal procedures are detailed in the "RMM_details" document which is attached in section 13 of the  Registration Dossier.