Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
equivalent or similar to guideline
Guideline:
ISO No., other: DIN EN ISO 2719
Deviations:
no
Principles of method if other than guideline:
Pensky-Martens apparatus
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
closed cup
Flash point:
136 °C
Atm. press.:
101 325 Pa
Conclusions:
The flash point of the substance was measured at 136.0 °C.
Executive summary:

The flash point was determined by following EU guideline A.9. (DIN EN ISO 2719). The flash point of the substance was measured at 136.0 °C.

Description of key information

The flash point of the substance was measured at 136.0 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
136 °C

Additional information