Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Principles of method if other than guideline:
No details are reported. The typical method used within the respective temperature range is Pensky-Martens according DIN 51758.
Type of method:
open cup
Key result
Flash point:
88 °C
Atm. press.:
1 013 hPa
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test item is 88°C.

Description of key information

The flash point of the test item is 88°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
88 °C

Additional information