Registration Dossier

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: guidance followed, no GLP

Data source

Referenceopen allclose all

Reference Type:
study report
Title:
Unnamed
Year:
2008
Report Date:
2008
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report Date:
2008

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 103 (Boiling point/boiling range)
Deviations:
no
GLP compliance:
no
Type of method:
photocell detection

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Boiling pointopen allclose all
Boiling pt.:
ca. 235 °C
Atm. press.:
ca. 101 325 Pa
Decomposition:
no
Remarks on result:
other: nehyzb
Boiling pt.:
ca. 223.7 °C
Atm. press.:
ca. 101 325 Pa
Decomposition:
no
Remarks on result:
other: hyzb

Any other information on results incl. tables

first sample (nehyzb):

Correction of boiling point: YES

Standard deviation: 0.4 °C

Average boiling point: 235.0 ± 0.4 °C at 101.325 kPa

second sample(hyzb):

Correction of boiling point: YES

Standard deviation: 0.3 °C

Average boiling point: 223.7 ± 0.3 °C at 101.325 kPa

Applicant's summary and conclusion

Conclusions:
boiling point could vary due to variable composition