Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: 92/69/EWG, A.4 (Dynamische Methode)
GLP compliance:
yes (incl. certificate)
Type of method:
dynamic method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Name of test material (as cited in study report): 3,6,9,12-Tetraoxotetradeca-1,13-dien
Analytical purity: 98,4 weight% determined by gas chromatographie (see study 96L00347)
Lot/batch No.: 3401/95-09

Results and discussion

Vapour pressureopen allclose all
Temp.:
20 °C
Vapour pressure:
0.004 hPa
Temp.:
50 °C
Vapour pressure:
0.091 hPa