Registration Dossier

Administrative data

Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1996
Report Date:
1996

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Name of test material (as cited in study report): Triethylenglykoldivinylether
Analytical purity: 98,4 weight% determined by gas chromatographie (see study 96L00347)
Lot/batch No.: 3401/95-09

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
200 °C
Atm. press.:
1 004 - 1 010 hPa
Remarks on result:
other:

Applicant's summary and conclusion