Registration Dossier

Administrative data

Endpoint:
pH
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2011-07-18 to 2011-07-19
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was conducted using an appropriate test method and in accordance with GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report Date:
2011

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EPA OPPTS 830.7000 (pH)
Deviations:
no
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent

Results and discussion

pH value
pH value:
5.3
Temp.:
24.8 °C
Concentration:
1 vol%

Any other information on results incl. tables

The pH of 1% test article was 5.29 at 24.76°C. The PDM indicates that acetic acid was removed from the reaction. Thus the slightly acidic pH would be consistent with small amounts of acetic acid not completely removed.

Applicant's summary and conclusion

Conclusions:
A pH of 5.3 at 24.76°C was determined for the substance in accordance with an appropriate test method and in compliance with GLP. The result is considered reliable.