Registration Dossier

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
October 4, 2007- January 19, 2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study has been performed according to OECD and EU guidelines and according to GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report Date:
2008

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
OECD Guideline 103 (Boiling point/boiling range)
Deviations:
no
Qualifier:
according to
Guideline:
EU Method A.2 (Boiling Temperature)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
differential scanning calorimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): Corsair Resin 5
- Substance type: UVCB
- Physical state: beige solid granules
- Stability under test conditions: stable
- Storage condition of test material: At room temperature in the dark

Results and discussion

Boiling point
Decomposition:
yes
Decomp. temp.:
> 400 °C

Applicant's summary and conclusion

Conclusions:
Reaction and/or decomposition of the test substance were observed above 400°C: boiling of Corsair Resin 5 was not observed below 400°C. Therefore, the test substance has no boiling temperature.