Registration Dossier

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
October 4, 2007- January 19, 2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study has been performed according to OECD and EU guidelines and according to GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report Date:
2008

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Deviations:
no
Qualifier:
according to
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
other: Differential Scanning Calorimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): Corsair Resin 5
- Substance type: UVCB
- Physical state: beige solid granules
- Stability under test conditions: stable
- Storage condition of test material: At room temperature in the dark

Results and discussion

Melting / freezing point
Melting / freezing pt.:
116 - 119 °C
Atm. press.:
101.325 kPa
Decomposition:
no

Applicant's summary and conclusion

Conclusions:
Using differential scanning calorimetry, the melting temperature of Corsair Resin 5 is between 116-119 ºC.