Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2007-11-07 - 2008-06-09
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
non GLP:
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
Directive 92/69/EEC, Official Journal L 383 A 1992, Pensky-Martens method, ASTM D93
GLP compliance:
no
Type of method:
closed cup
Flash point:
129 °C
Atm. press.:
1 013 hPa
Conclusions:
The flash point is reported to be 129 °C at 1013 hPa according to Pensky-Martens ASTM D 93 method (closed cup).
Executive summary:

The flash point is reported to be 129 °C at 1013 hPa according to Pensky-Martens ASTM D 93 method (closed cup).

Description of key information

Flash point: 129 °C at 1013 hPa (Evonik Röhm Services, 2008)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
402 K

Additional information

The flash point of N-[3-(dimethylamino)propyl]methacrylamide is reported to be 129 °C (closed cup) according to EU Directive 92/69/EEC, Official Journal L 383 A 1992, Pensky-Martens method, ASTM D93.