Registration Dossier

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2001
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: The study was done following a method in compliance with ISO 17025 but with deviations.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2001
Report date:
2001

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO No., other: DIN EN 22719
Deviations:
yes
Remarks:
(Single determination only.)
GLP compliance:
no
Remarks:
ISO 17025 compliance
Type of method:
closed cup

Test material

Constituent 1
Reference substance name:
Laurylimidazole
IUPAC Name:
Laurylimidazole
Details on test material:
- Name of test material (as cited in study report): Laurylimidazol

Results and discussion

Flash point
Flash point:
226 °C
Remarks on result:
other: No pressure was reported.

Applicant's summary and conclusion

Conclusions:
Laurylimidazole has a flash point of 226°C.
Executive summary:

The flash point was determined using a Pensky-Martens closed cup flash point apparatus. Few details were provided, but the DIN EN 22719 method was followed. The laboratory didn’t have enough test material for a duplicate test. The use of Pensky-Martens apparatus is approved for this endpoint per EC no. 92/69/EEC, Part A.9: "Flash-Point". Therefore this study is classified as reliable with restrictions.