Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 208-760-7 | CAS number: 540-88-5
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Exposure related observations in humans: other data
Administrative data
- Endpoint:
- exposure-related observations in humans: other data
- Type of information:
- experimental study
- Adequacy of study:
- supporting study
- Study period:
- Mutiple short exposures over a maximum 12-hour period
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: Study conducted according to generally accepted methodology for this type of study.
Data source
Reference
- Reference Type:
- publication
- Title:
- Can we trust odor databases? Example of t- and n-butyl acetate
- Author:
- Cain WS and Schmidt R
- Year:
- 2 009
- Bibliographic source:
- Atmospheric Environment 43: 2591-2601
Materials and methods
- Type of study / information:
- This study investigated the chemosensory properties of tertiary butyl acetate. In one study, volunteer subjects were asked to detect the odor of tertiary butyl acetate. In the second study, subjects were asked to detect the presence of vapor with the eye via chemesthesis (sensory irritation) in 10 second exposures.
- Endpoint addressed:
- eye irritation
Test guideline
- Qualifier:
- no guideline followed
- Deviations:
- not applicable
- Principles of method if other than guideline:
- Study 1: Odor Detection
Twenty three young adult male and female subjects (average age of 22 years) participated in the study. The test was conducted over a period of 12 hours, generally in 6-hr blocks broken in halves with a lunch break. A block would provide at least 240 judgments. Each exposure lasted about 2 seconds/sniff so total exposure over a 6-hr period was about 8 minutes. Test chemical was diluted with nitrogen and different test vapor concentrations were delivered to a series of sampling cones. Test subjects sampled the cones and rated their ability to detect the odor of tertiary butyl acetate on a scale from 1 (very low) to 5 (very high).
Study 2: Ocular Detection
This study compared the concentration of tertiary butyl acetate necessary to cause sensory irritation with the odor recognition threshold in Study 1. Twenty four young adult male and female subjects (average age 22 years) participated in the study. The test covered a period of 6 hours which included at least 180 trials, 30 cycles for six concentrations. Complete testing equaled 15 min per eye. A series of vapor generating stations delivered vapors over the range 21-670 ppm. Polyethylene cyclinders delivered the test material to the eyes at a flow rate of 10 L/min and a linear air speed of 8.6 cm/s. Each station had two cylinders, one for each eye. For each exposure cycle, test vapor was randomly delivered to one eye while the other eye was exposed to blank air. Each exposure was for a maximum of 10 seconds with a 30-sec time-out between exposures. Subjects terminated exposure early if sensation was detected in less than 10 seconds.
In both series of tests, values were determined for concentrations that gave 50% detection for the test subjects. - GLP compliance:
- no
- Remarks:
- Human studies are not subject to GLP compliance.
Test material
- Reference substance name:
- tert-butyl acetate
- EC Number:
- 208-760-7
- EC Name:
- tert-butyl acetate
- Cas Number:
- 540-88-5
- Molecular formula:
- C6H12O2
- IUPAC Name:
- tert-butyl acetate
- Reference substance name:
- tertiary butyl acetate
- IUPAC Name:
- tertiary butyl acetate
- Details on test material:
- -Name of test material (as used in publication): t-butyl acetate
-Source: Acros Organics, Fair Lawn NJ USA
-Lot #: A0196138001
-Purity: > 99%
Constituent 1
Constituent 2
Method
- Ethical approval:
- confirmed and informed consent free of coercion received
- Details on study design:
- Study 1: Odor Detection
Twenty three young adult male and female subjects (average age of 22 years) participated in the study. The test was conducted over a period of 12 hours, generally in 6-hr blocks broken in halves with a lunch break. A block would provide at least 240 judgments. Each exposure lasted about 2 seconds/sniff so total exposure over a 6-hr period was about 8 minutes. Test chemical was diluted with nitrogen and different test vapor concentrations were delivered to a series of sampling cones. Test subjects sampled the cones and rated their ability to detect the odor of tertiary butyl acetate on a scale from 1 (very low) to 5 (very high).
Study 2: Ocular Detection
This study compared the concentration of tertiary butyl acetate necessary to cause sensory irritation with the odor recognition threshold in Study 1. Twenty four young adult male and female subjects (average age 22 years) participated in the study. The test covered a period of 6 hours which included at least 180 trials, 30 cycles for six concentrations. Complete testing equaled 15 min per eye. A series of vapor generating stations delivered vapors over the range 21-670 ppm. Polyethylene cyclinders delivered the test material to the eyes at a flow rate of 10 L/min and a linear air speed of 8.6 cm/s. Each station had two cylinders, one for each eye. For each exposure cycle, test vapor was randomly delivered to one eye while the other eye was exposed to blank air. Each exposure was for a maximum of 10 seconds with a 30-sec time-out between exposures. Subjects terminated exposure early if sensation was detected in less than 10 seconds.
In both series of tests, values were determined for concentrations that gave 50% detection for the test subjects. - Exposure assessment:
- measured
- Details on exposure:
- For Study 1, an eight-station vapor delivery device was used to present the test concentrations ranging from 0.5 to 66 ppb. Test chemical was diluted with nitrogen to achieve desired concentrations. Test concentrations were measured by gas chromatography with flame ionization detector. For each cycle, a computerized voice directed test subjects to sample sequential glass cones at 5-second intervals. The test subject indicated which cone appeared to deliver odorant and the confidence in the choice on a scale of 1 (very low) to 5 (very high). There was a 15-second time-out between each of the eight trials and a 5-10 min period between cycles.
For Study 2, the same delivery system was used with some modifications: (1) only six stations were used and the test concentrations ranged from 21-670 ppm and (2) polyethylene cylinders instead of glass cones delivered the vapor concentrations to the eyes. For each trial, the test subjects placed the cyclinders to their closed eyes and when directed by a computerized voice, opened their eyes for a 10-second exposure. After exposures, subjects were directed to move to the next station where a 30-second time-out occurred before the next exposure.
Results and discussion
- Results:
- For odor threshold, the mean values for % correct detection were similar for males and females. Using the 50% criterion, the odor threshold for tertiary butyl acetate for the test subjects in this study was 8 ppb with a geometric standard deviation of 2.47. Most subjects showed less than threefold variation from the mean.
For chemesthesis (sensory eye irritation), the mean values for % correct detection were similar for males and females. Using the 50% criterion, the threshold for ocular irritation for tertiary butyl acetate for the test subjects in this study was 177 ppm with a geometric standard deviation of 1.6. Most subjects showed less than twofold variation from the mean.
These data can also be used to calculate a Reference Concentration (RfC) for tertiary butyl acetate. The short-term (10 second) threshold for ocular irritation (trigeminal nerve stimulation) in humans was 177 ppm for typical individuals. The psychometric function for ocular detection (Z = 3.13 log Cppm – 7.22) can be used to calculate the concentration at which no detection would occur (Z = -2 at 47 ppm). Therefore, the LOAEL for typical humans was 177 ppm and the NOAEL was 47 ppm. The NOAEL to LOAEL uncertainty factor for irritation was 3.77.
Based on the psychometric function for cumulative performance, at 47 ppm, even the most sensitive individual would not feel the presence of vapor 50% of the time. Using 47 ppm as the LOAEL for sensitive groups and the psychometric function for eye irritation, a NOAEL of 11 ppm can be calculated for this group (Z = -4).
Applicant's summary and conclusion
- Conclusions:
- There are numerous published studies and databases that have been used to set safety thresholds for chemical exposure based on odor potency. These data may differ by several orders of magnitude for the same chemical. In a study designed to compare the odor threshold for tertiary butyl acetate with the vapor concentration needed to detect vapor with the eye via chemesthesis (sensory irritation), the level needed to cause chemesthesis (177 ppm) was more than 10,000 times above that for odor detection (8 ppb).
The psychometric function for ocular detection was used to calculate the concentration at which no detection would occur. The LOAEL for typical humans (50% detection) was 177 ppm and the NOAEL was 47 ppm. Based on this information, at 47 ppm, even the most sensitive individual would not feel the presence of vapor 50% of the time. Then, using 47 ppm as the LOAEL for the sensitive group, a NOAEL of 11 ppm could be calculated for this group. - Executive summary:
In a study to investigate the chemosensory properties of tertiary butyl acetate, male and female test subjects were exposed to analytically verified vapor concentrations of the test material in a controlled setting and asked to judge odor and sensory irritation. Data values were reported as the points of 50% detection above chance. For tertiary butyl acetate, the odor threshold occurred at 8 ppb. For sensory irritation, detection at 50% occurred at 177 ppm. There were no significant differences in response between male and female test subjects for either odor detection threshold or sensory irritation threshold. The LOAEL for sensory irritation for typical test subjects was 177 ppm and the NOAEL was 47 ppm. The LOAEL for sensitive individuals was considered to be 47 ppm and the NOAEL 11 ppm.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.