Administrative data

First-aid measures

General advice:
First Aid responders should pay attention to self-protection and use the recommended protective clothing (chemical resistant gloves, splash protection). If potential for exposure exists refer to Section 8 of SDS for specific personal protective equipment.

Inhalation: Move person to fresh air; if effects occur, consult a physician.

Skin contact: Wash off with plenty of water. Suitable emergency safety shower facility should be available in work area.

Eye contact: Flush eyes thoroughly with water for several minutes. Remove contact lenses after the initial 1-2 minutes and continue flushing for several additional minutes. If effects occur, consult a physician, preferably an ophthalmologist. Suitable emergency eye wash facility should be available in work area.

Ingestion: Do not induce vomiting. Call a physician and/or transport to emergency facility immediately.

Indication of any immediate medical attention and special treatment needed
Notes to physician: The decision of whether to induce vomiting or not should be made by a physician. If lavage is performed, suggest endotracheal and/or esophageal control. Danger from lung aspiration must be weighed against toxicity when considering emptying the stomach. No specific antidote. Treatment of exposure should be directed at the control of symptoms and the clinical condition of the patient.

Fire-fighting measures

Suitable extinguishing media:
Water fog or fine spray
Dry chemical fire extinguishers
Carbon dioxide fire extinguishers
Foam
General purpose synthetic foams (including AFFF type) or protein foams are preferred if available.
Alcohol resistant foams (ATC type) may function.

Unsuitable extinguishing media:
Do not use direct water stream. Straight or direct water streams may not be effective to extinguish fire..

Special hazards arising from the substance or mixture:
Hazardous combustion products: During a fire, smoke may contain the original material in addition to combustion products of varying composition which may be toxic and/or irritating.
Combustion products may include and are not limited to:. Carbon monoxide.. Carbon dioxide..

Unusual Fire and Explosion Hazards:
Container may vent and/or rupture due to fire
Electrically ground and bond all equipment
Flammable mixtures of this product are readily ignited even by static discharge.
Vapors are heavier than air and may travel a long distance and accumulate in low lying areas.
Ignition and/or flash back may occur.
Flammable mixtures may exist within the vapor space of containers at room temperature.
Flammable concentrations of vapor can accumulate at temperatures

Advice for firefighters

Fire Fighting Procedures: Keep people away. Isolate fire and deny unnecessary entry. Stay upwind. Keep out of low areas where gases (fumes) can accumulate. Water may not be effective in extinguishing fire. Use water spray to cool fire exposed containers and fire affected zone until fire is out and danger of reignition has passed.. Immediately withdraw all personnel from the area in case of rising sound from venting safety device or discoloration of the container.. Do not use direct water stream. May spread fire. Eliminate ignition sources. Move container from fire area if this is possible without hazard.Burning liquids may be moved by flushing with water to protect personnel and minimize property damage. Avoid accumulation of water. Product may be carried across water surface spreading fire or contacting an ignition source. Contain fire water run-off if possible. Fire water run-off, if not contained, may cause environmental damage.

Special protective equipment for firefighters: Wear positive-pressure self-contained breathing apparatus (SCBA) and protective fire fighting clothing (includes fire fighting helmet, coat, trousers, boots, and gloves). Avoid contact with this material during fire fighting operations. If contact is likely, change to full chemical resistant fire fighting clothing with self- contained breathing apparatus. If this is not available, wear full chemical resistant clothing with self-contained breathing apparatus and fight fire from a remote location.. For protective equipment in post-fire or non-fire clean-up situations, refer to the relevant sections..

Accidental release measures

Personal precautions, protective equipment and emergency procedures: Evacuate area. Refer to section 7 Handling and Storgage, for additional precautionary measures. Only trained and properly protected personnel must be involved in clean-up operations. Keep personnel out of low areas. Keep personnel out of confined or poorly ventilated areas. Keep upwind of spill. Ventilate area of leak or spill. Vapor explosion hazard. Keep out of sewers. Eliminate all sources of ignition in vicinity of spill or released vapor to avoid fire or explosion. For large spills, warn public of downwind explosion hazard. Check area with combustible gas detector before reentering area. Ground and bond all containers and handling equipment.

Environmental precautions: Prevent from entering into soil, ditches, sewers, waterways and/or groundwater. See Section 12, Ecological Information. Material may float on water and any runoff may create an explosion or fire hazard if ignited.

Methods and materials for containment and cleaning up: Contain spilled material if possible. Small spills: Absorb with materials such as: Clay. Dirt. Large spills: Dike area to contain spill. Pump with explosion-proof equipment. If available, use foam to smother or suppress. Ground and bond all containers and handling equipment. Collect in suitable and properly labeled containers.

Handling and storage

Precautions for safe handling: Keep away from heat, sparks and flame. Avoid contact with eyes, skin, and clothing. Do not swallow. Avoid breathing vapor. Wash thoroughly after handling. Keep container closed. Use with adequate ventilation. No smoking, open flames or sources of ignition in handling and storage area. Vapors are heavier than air and may travel a long distance and accumulate in low lying areas. Ignition and/or flash back may occur. Handling operations that can promote accumulation of static charges include but are not limited to mixing, filtering, pumping at high flow rates, splash filling, creating mists or sprays, tank and container filling, tank cleaning, sampling, gauging, switch loading, vacuum truck operations. Electrically bond and ground all containers, personnel and equipment before transfer or use of material. Use of non-sparking or explosion-proof equipment may be necessary, depending upon the type of operation. Never use air pressure for transferring product. Containers, even those that have been emptied, can contain vapors. Do not cut, drill, grind, weld, or perform similar operations on or near empty containers. Do not enter confined spaces unless adequately ventilated. This product is a poor conductor of electricity and can become electrostatically charged, even in bonded or grounded equipment. If sufficient charge is accumulated, ignition of flammable mixtures can occur.

Conditions for safe storage, including any incompatibilities: Flammable mixtures may exist within the vapor space of containers at room temperature. Keep container closed. Minimize sources of ignition, such as static build-up, heat, spark or flame.

Specific end use(s): See the technical data sheet on this product for further information.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
1268
Shipping information
Proper shipping name and description:
PETROLEUM DISTILLATES, N.O.S.
Special provisions / remarks
Special provisions:
pecial Provision 640D
Hazard Identification Number: 33
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
1268
Shipping information
Proper shipping name and description:
PETROLEUM DISTILLATES, N.O.S.
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
1268
Shipping information
Proper shipping name and description:
Petroleum distillates, n.o.s.
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Substance registered as an isolated or transported intermediate. Substance handled under Strictly conctrolled conditions

Stability and reactivity

Disposal considerations