Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018-03-12 - 2018-03-16
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
Deviations:
no
GLP compliance:
yes
Type of method:
flask method
Partition coefficient type:
octanol-water

Test material

Constituent 1
Chemical structure
Reference substance name:
[8,20-dihydro-8,20-diphenyl-5,24:12,17-diimino-7,10:22,19-dinitrilodibenz[f,p][1,2,4,9,11,12,14,19]octaazacycloicosinato(2-)-N25,N26,N27,N28]iron
EC Number:
256-526-8
EC Name:
[8,20-dihydro-8,20-diphenyl-5,24:12,17-diimino-7,10:22,19-dinitrilodibenz[f,p][1,2,4,9,11,12,14,19]octaazacycloicosinato(2-)-N25,N26,N27,N28]iron
Cas Number:
50293-39-5
Molecular formula:
C32H18FeN12
IUPAC Name:
[8,20-dihydro-8,20-diphenyl-5,24:12,17-diimino-7,10:22,19-dinitrilodibenz[f,p][1,2,4,9,11,12,14,19]octaazacycloicosinato(2-)-N25,N26,N27,N28]iron
Test material form:
solid
Remarks:
dark brown
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: sponsor

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: Refrigerated (5 ± 3°C)

Study design

Analytical method:
high-performance liquid chromatography

Results and discussion

Partition coefficientopen allclose all
Key result
Type:
log Pow
Partition coefficient:
2.88
Temp.:
23 °C
pH:
>= 3 - <= 3.2
Type:
Pow
Partition coefficient:
753.7
Temp.:
23 °C
pH:
>= 3 - <= 3.2

Applicant's summary and conclusion

Conclusions:
The study was performed according to OECD TG 107 under GLP on the substance to be registered itself, the test procedure is well documented and therefore reliability of Klimisch 1 has been assigned. OECD 107 states that the six determined log Pow values should fall within a range of ± 0.3 units. This criterion is fulfilled, and the partition coefficient can be reported as total average over six independent determinations:
Pow = 753.7 (standard deviation 178.3)
log Pow = 2.88
The pH value of the aqueous buffer phases varied between 3.0 and 3.2. The partition coefficient was determined at 23 °C.
Executive summary:

The partition coefficient of the test item was determined according to OECD Guideline for the testing of chemicals 107 under GLP, shake flask method.

Results:

Pow = 753.7 (standard deviation 178.3)

logPow = 2.88