Endpoint:
flammable liquids: obsolete as covered by section 'Flash point'
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
appearance / physical state / colour
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November, 2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Appearance based on observations from other testing endpoints conducted for this substance
Reason / purpose for cross-reference:
reference to other study
Principles of method if other than guideline:
Observations based on the observations made during testing for other endpoints
GLP compliance:
yes
Physical state at 20°C and 1013 hPa:
liquid
Key result
Form:
liquid: viscous
Colour:
Clear
Odour:
other: Characteristic
Substance type:
organic
Conclusions:
The substance is a viscous liquid witha clear appearance.
Executive summary:

The physical state and appearance of the test substance were visually observed during testing of other endpoints. The purified form of the test substance is a viscous liquid with a clear appearance (Scymaris, 2017).

Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From September 02, 2017 to September 19, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
EU Regulation (EC) 440/2008, Annex Part A test A9
Deviations:
not specified
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Atm. press.:
ca. 100.9 - ca. 101.2 kPa
Remarks on result:
no flash point - measurement carried out until boiling temperature

Full test results:

Temperature (°C)

Barometric Pressure (kPa)

Ignition?

Yes (y) / No (n)

Halo/Enlarged test flame? Yes (y) / No (n)

Run 1

25.0 – 215.0*

100.9

N

N/A

Run 2

25.0 – 215.0*

101.2

N

N/A

* Due to the test substance boiling, higher test temperatures could not be attained and therefore testing was terminated.

Interpretation of results:
GHS criteria not met
Remarks:
No flash point was observed until boiling of the test substance at 215°C
Conclusions:
Under the study conditions, the flash point of the test substance could not be determined.
Executive summary:

A study was conducted to determine the flash point of the test substance using the closed cup method according to EU Method A.9. Due to the test substance boiling at 215°C, higher test temperatures could not be attained and therefore the testing was terminated. Under the study conditions, the flash point of the test substance could not be determined (Chilworth, 2017).

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion