Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Oxidising properties

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
oxidising liquids
Type of information:
other: Expert Statement
Adequacy of study:
key study
Study period:
10 August to 11 August 2015
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Valid and conclusive statement
Qualifier:
according to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
Deviations:
no
Principles of method if other than guideline:
- The chemical structure of the test item provided by the Sponsor was assessed for chemical groups that would imply oxidizing properties. - Examples of such groups are nitrates, metal oxides, hypofluorites, difluoroaminopolynitroaryls, perchlorates, bromates and iodites.
- Full structural details are given in Bretherick's Handbook of Reactive Chemical Hazards, 7th Edition, Academic Press, 2007.
GLP compliance:
yes (incl. QA statement)
Key result
Sample tested:
other: prediction
Parameter:
other: assessment of chemical structure
Remarks on result:
other: oxidising properties predicted negative as no structural alerts were identified in the test item

No structural alerts were found within the chemical structure of the test item.

Interpretation of results:
GHS criteria not met
Conclusions:
Based on the idealised chemical structure of the test item the result for the oxidizing properties has been predicted negative.
Executive summary:

GUIDELINE

Oxidising properties were predicted using a procedure designed to be compatible with Method A.21 Oxidising Properties (Liquids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

CONCLUSION

Based on the idealised chemical structure of the test item the result for oxidising properties has been predicted negative.

Endpoint:
oxidising liquids
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Reason / purpose for cross-reference:
read-across source
Sample tested:
other: prediction
Parameter:
other: assessment of chemical structure
Remarks on result:
other: oxidising properties predicted negative as no structural alerts were identified in the test item

Description of key information

The chemical structure of the analogue test item was assessed and the resulting expert statement concludes that the test item does not have oxidising properties (EU Method A.21).

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

GUIDELINE

Oxidising properties were predicted using a procedure designed to be compatible with Method A.21 Oxidising Properties (Liquids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

CONCLUSION

Based on the chemical structure of the analogue test item the result for oxidising properties has been predicted negative.

Justification for classification or non-classification

Based on the chemical structure of the analogue test item the result for oxidising properties has been predicted negative.