Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Description of first aid measures

General information: In case of accident or if you feel unwell, seek medical advice immediately (show safety data sheet if possible).

Following inhalation: Seek medical advice. Remove person to fresh air and keep comfortable for breathing. In case of irregular breathing or respiratory arrest provide artificial respiration.

After skin contact: Immediately remove any contaminated clothing, shoes or stockings. After contact with skin, wash immediately with plenty of water and soap. In case of skin irritation, seek medical treatment

Following eye contact: In case of contact with eyes, rinse immediately with plenty of flowing water for 10 to 15 minutes holding eyelids apart. Subsequently consult an ophthalmologist.

After ingestion: Rinse mouth thoroughly with water. Seek medical advice.

Self-protection of the first aider: First aid assistant: Pay attention to self-protection!

Most important symptoms and effects, both acute and delayed

Harmful if swallowed.

Harmful if inhaled.

If skin irritation occurs it may be harmful.

In contact with eyes may cause irritation.

Indication of any immediate medical attention and special treatment needed

No data available (investigational product).

Fire-fighting measures

Extinguishing media

Suitable extinguishing media: Sand, Carbon dioxide (CO2), Dry extinguishing powder.

Extinguishing media which must not be used for safety reasons: No data available.

Special hazards arising from the substance or mixture

Carbon dioxide (CO2) and nitrogen oxides (NOx) can be produced.

Advice for fire-fighters

Wear self-contained breathing apparatus and full protective clothing.

Additional information

No data available.

Accidental release measures

Personal precautions, protective equipment and emergency procedures

Avoid inhalation of the product and contact with eyes and skin.

Provide fresh air and adequate ventilation in closed rooms.

See protective measures under point 7 and 8.

Environmental precautions

Do not empty into drains or the aquatic environment. Notify authorities if product enters sewers or public waters.

Methods and material for containment and cleaning up

Clear contaminated area thoroughly.

Pick up and arrange disposal without creating dust.

Collect in closed containers for disposal.

Dispose of waste product or used containers according to local regulations.

Reference to other sections

See protective measures under section Exposure controls/personal protection and section Disposal considerations

Handling and storage

Precautions for safe handling

Ensure adequate ventilation.

Avoid inhalation of the product.

Avoid contact with eyes and skin.

Do not eat, drink, or smoke during use or in storage areas.

Before using the product, make sure that the container that will be used is appropriate and is clean.

Make sure that the containers are properly labeled and away from flammable, corrosive or explosive.

Use personal protective equipment.

Read the label before use.

Avoid splashing.

Conditions for safe storage, including any incompatibilities

Keep container tightly closed.

Keep away from heat sources and direct sunlight.

Store locked up.

Store in a well-ventilated place.

Specific end use(s)

Reference standard.

Manufacture of Active Pharmaceutical Ingredients (APIs).

Handle the substance under strictly controlled conditions according to Article 18(4) of REACH Regulation. Rigorous containment should be achieved.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Additional transport information

Additional information
Special provisions / remarks / other:
Not regulated for transport. No special precautions.

Exposure controls / personal protection

Control parameters

No data available (investigational product).

Exposure controls

Appropriate engineering controls

Avoid all unnecessary exposure. Good ventilation in working area.

Individual protection measures, such as personal protective equipment

Respiratory protection: Safe mask: FFP1.

Hand protection:  Suitable gloves type: Nitrile and Latex.

Eye protection: Wear closed protection glasses or goggles.

Skin protection: Wear suitable protective clothing. Protective clothing should be specifically selected depending on quantity of substance handled.

General protection and hygiene measures: Wash hands before breaks and after work. When using do not eat, drink or smoke.

Thermal hazards: No data available.

Environmental exposure controls

Do not empty into drains or the aquatic environment. Comply with the environmental local regulation currently in force.

The substance is used under strictly controlled conditions during its whole lifecycle as described under Article 18(4) and Section 2.1 of the Guidance for Intermediates. The substance should be rigorously contained by technical means during its whole lifecycle and procedural and control technologies should be in place in order to minimize emissions and any resulting exposure as described under Article 18(4). Personal protective equipment (PPE) should be used in cases of accidents and where waste is generated. The PPE may be also used as a good practice.

Stability and reactivity

Reactivity

No data available (investigational product).

Chemical stability

Stable 5 years minimum (< 25ºC).

Possibility of hazardous reactions

No data available (investigational product).

Conditions to avoid

Keep away from heat sources and direct sunlight.

Incompatible materials

No data available (investigational product).

Hazardous decomposition products

No data available (investigational product).

Disposal considerations

Waste treatment methods

External treatment and disposal of waste should comply with applicable local/regional/national/international regulations.

The product will be disposed of in accordance with the regulation currently in force and specifically with:

- Directive 2008/98/EC, of 19 November 2008 on waste and the corresponding national regulations which transpose this Directive.

- Directive 94/62/EC, of 20 December 1994 on packaging and packaging waste and its modifications and corresponding national regulations which transpose this Directive.

- Commission Decision 2001/118/EC of 16 January 2001 amending Decision 2000/532/EC as regards the list of wastes and any other regulation currently in force in the European Community, National and Local with regard to the correct disposal of this material and its empty containers.