First-aid measures

Inhalation: Remove from danger zone. Obtain immediate medical assistance
Skin Contact: Remove contaminated clothing. Rinse contaminated skin immediately with plenty of water and seek medical advice.
Eye Contact: Immediately rinse eyes thoroughly with running water as long as possible (approx. 15 min).
Take injured quickly to factory medical center or call an ambulance (code word: eye accident).
Ingestion: If swallowed, seek medical advice immediately and show this container or label.

Fire-fighting measures

Fire-fighting measures: Wear self-contained breathing apparatus and fire protective suite.
Suitable Extinguishing Media: Water spray or fog, foam, dry chemical powder, CO2, dry sand
Unsuitable Extinguishing Media: No restrictions

Accidental release measures

Accident release measures: All equipment and protective garments must be either decontaminated or properly contained for disposal before leaving the area.

Handling and storage

Handling storage: Provide appropriate exhaust ventilation at machinery and at places where dust can be generated. Keep container tightly closed in a dry, cool and well-ventilated place. Avoid formation of dust.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
not classified
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
not classified
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
not classified
Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
not classified
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Industrial Hygiene The personal protective measure may be adapted appropriately when working in closed systems or under laboratory conditions.
Regular cleaning of equipment, work area and clothing.
No open handling without using reliable equipment. One technical barrier between substance and employee resp. environment.
Restricted and controlled access for trained personnel only.
Designated washing, changing and shower facilities must be available.
Internal working procedures available to personnel covering personal hygiene, decontamination /cleaning, consideration of worst case incidents, spills, emergency, alarms, waste disposal and maintenance.
Personnel comprehensively instructed, highly trained and experienced. Regular refresher training established including appropriate record keeping.
Equipment and protective garments must either be decontaminated or properly contained for disposal before leaving the area.
Disposable protective equipment is to be decontaminated before removal (decontamination shower).
Open Handling Respiration : Full face mask (EN149) or reusable half mask (EN140)
Filter : P3 (EN143)
Eye : safty glassess (EN166)
Hand : Normal length chemical-mechanical-resistant gloves (EN374/EN388)


worn over disposable gloves
Glove Material : Nitrile
Breakthrough time: 240 min
Thickness: 0.4 mm
Additional protection : working clothes (EN 340)
Disposable boot covers, conductive

Stability and reactivity

Stable at normal conditions
Preventive Precautions (fire/explosion)
Take precautionary measures against static discharges. Keep away from sources of ignition.
Hazardous decomposition products: carbon oxides, nitrogen oxides, hydrofluoric acid (Hydrogen fluoride), sulfur oxides

Disposal considerations

Fill into suitable waste receptacles, seal and label them properly. Incineration in an approved, controlled furnace with combustion gas scrubbing and emission gas control