Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Description of first aid measures
Inhalation:
Remove exposed person to fresh air if adverse effects are observed.

Eye contact:
Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get
medical advice/attention.

Skin Contact:
Take off contaminated clothing and wash before re-use. Wash skin thoroughly with soap and water. If skin irritation or rash occurs: Get
medical attention. Launder contaminated clothing before reuse.

Ingestion:
Rinse mouth. Get medical attention if symptoms occur.

Treatment: Treat symptomatically.

Fire-fighting measures

General Fire Hazards:
No unusual fire or explosion hazards noted.

Extinguishing media
Suitable extinguishing media:
CO2, Dry chemical or Foam. Water can be used to cool and protect exposed material.

Unsuitable extinguishing media:
Not determined.

Special hazards arising from the substance or mixture:
Water may cause splattering.

Special protective equipment for fire-fighters:
Recommend wearing self-contained breathing apparatus.

Accidental release measures

Personal precautions, protective equipment and emergency procedures:
Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Keep unauthorized personnel away.

Environmental Precautions:
Do not contaminate water sources or sewer. Prevent further leakage or spillage if safe to do so.

Methods and material for containment and cleaning up:
Dike far ahead of larger spill for later recovery and disposal. Pick up free liquid for recycle and/or disposal. Residual liquid can be absorbed on inert
material. Stop the flow of material, if this is without risk. Prevent entry into waterways, sewer, basements or confined areas.

Handling and storage

Precautions for safe handling:
Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or grounding procedures.
Use grounding and bonding connection when transferring material. In case of spills, beware of slippery floors and surfaces.
This long chain alkenyl ester may be held at 60 C for a maximum of 6 hours. Holding the material hot for a longer period may cause darkening in
color or possible decomposition.
Avoid breathing dust/fume/gas/mist/vapors/spray. Avoid contact with eyes, skin, and clothing. Avoid contact with eyes. Observe good industrial
hygiene practices. Provide adequate ventilation. Wear appropriate personal protective equipment. Wash hands thoroughly after handling. Contaminated work clothing should not be allowed out of the workplace. Launder contaminated clothing before reuse.

Conditions for safe storage, including any incompatibilities:
Store away from incompatible materials.

TRGS 510 Storage Class: Combustible liquids

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
Not regulated.
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
Not regulated.
Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
Not regulated.
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control Parameters
Occupational Exposure Limits
None of the components have assigned exposure limits.

Exposure controls
Appropriate engineering controls:
No special requirements under ordinary conditions of use and with adequate ventilation.

Individual protection measures, such as personal protective equipment
General information:
Please follow the recommended personal protective equipment (PPE) guidelines below and refer to the appropriate EN standard where
applicable. Provide easy access to water supply and eye wash facilities.
Good general ventilation (typically 10 air changes per hour) should be used.
Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls
to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an
acceptable level.

Eye/face protection:
Safety glasses. If potential for splash or mist exists, wear chemical goggles or faceshield. Eye protection should meet the standards set out in EN 166.

Skin protection
Hand Protection:
Use nitrile or neoprene gloves. Use good industrial hygiene practices. In case of skin contact, wash hands and arms with soap and water. Nitrile.

General:
Because specific work environments and material handling practices vary, safety procedures should be specific for each intended application. The
correct choice of protective gloves depends upon the chemicals being handled, and the conditions of work and use. Most gloves provide
protection for only a limited time before they must be discarded and replaced (even the best chemically resistant gloves will break down after
repeated chemical exposures). Gloves should be chosen in consultation with the supplier / manufacturer and taking account of a full assessment of
the working conditions. For typical use and handling of chemical substances, gloves should meet the standards set out in EN 374. For
applications involving mechanical risks with potential for abrasion or puncture, the standards set out in EN 388 should be considered. For tasks
involving thermal hazards, the standards set out in EN 407 should be considered.

Break-through time:
Breakthrough time data are generated by glove manufacturers under laboratory test conditions and represent how long a glove can be expected
to provide effective permeation resistance. It is important when following breakthrough time recommendations that actual workplace conditions are
taken into account. Always consult with your glove supplier for up-to-date technical information on breakthrough times for the recommended glove
type.
For continuous contact, we suggest gloves with a minimum breakthrough time of 240 minutes, or > 480 minutes if suitable gloves can be obtained. If
suitable gloves are not available to offer that level of protection, gloves with shorter breakthrough times may be acceptable as long as appropriate glove maintenance and replacement regimes are determined and adhered to.
For short-term, transient exposures and splash protection, gloves with shorter breakthrough times may commonly be used. Therefore, appropriate
maintenance and replacement regimes must be determined and rigorously followed.

Glove thickness:
For general applications, we recommend gloves with a thickness typically greater than 0.35 mm.
It is important to note that glove thickness is not the only predictor of glove resistance to a specific chemical, as the permeation efficiency of the glove will be dependent on the exact composition of the glove material.
Therefore, glove selection should also be based on consideration of the task requirements and knowledge of breakthrough times.
Glove thickness may also vary depending on the glove manufacturer, the glove type and the glove model. Therefore, the manufacturers’ technical
data should always be taken into account to ensure selection of the most appropriate glove for the task.

Note: Depending on the activity being conducted, gloves of varying thickness may be required for specific tasks. For example: Thinner gloves
(down to 0.1 mm or less) may be required where a high degree of manual dexterity is needed. However, these gloves are only likely to give short
duration protection and would normally be just for single use applications, before being disposed of. Thicker gloves (up to 3 mm or more) may be
required where there is a mechanical (as well as a chemical) risk i.e. where there is abrasion or puncture potential.
Other: Gloves, coveralls, apron, boots as necessary to minimize contact. Do not wear rings, watches or similar apparel that could entrap the material.

Respiratory Protection:
Use disposable dust/mist mask if the recommended exposure limit is exceeded. A respiratory protection program compliant with all applicable
regulations must be followed whenever workplace conditions require the use of a respirator. Under normal use conditions, respirator is not usually
required. Use appropriate respiratory protection if exposure to dust particles, mist or vapors is likely. Use self-contained breathing apparatus
for entry into confined space, for other poorly ventilated areas and for large spill clean-up sites.
Respiratory Protective Equipment (RPE) is not normally required where there is adequate natural or local exhaust ventilation to control exposure.
In case of insufficient ventilation, wear suitable respiratory equipment.
The correct choice of respiratory protection depends upon the chemicals being handled, the conditions of work and use, and the condition of the
respiratory equipment.
Safety procedures should be developed for each intended application. Respiratory protection equipment should therefore be chosen in
consultation with the supplier/manufacturer and with a full assessment of the working conditions.
Please refer to the relevant EN standards for the RPE selected.
Hygiene measures: Observe good industrial hygiene practices. Avoid contact with skin. Avoid contact with eyes. Contaminated work clothing should not be allowed out of the workplace.

Stability and reactivity

Chemical Stability:
Material is stable under normal conditions.

Possibility of hazardous reactions:
Will not occur.

Conditions to avoid:
Do not expose to excessive heat, ignition sources, or oxidizing materials.

Incompatible Materials:
Strong acids. Oxidizing agents. Strong oxidizing agents. Strong oxidizing agents.

Hazardous Decomposition Products:
Thermal decomposition or combustion may generate smoke, carbon monoxide, carbon dioxide, and other products of incomplete combustion.

Disposal considerations

Waste treatment methods
Disposal methods:
Treatment, storage, transportation, and disposal must be in accordance with applicable Federal, State/Provincial, and Local regulations.
Dispose of packaging or containers in accordance with local, regional, national and international regulations. Empty container contains product
residue which may exhibit hazards of product.

Contaminated Packaging: Container packaging may exhibit hazards.