Administrative data

First-aid measures

After inhalation: Supply fresh air; consult doctor in case of complaints.
After skin contact:
Immediately flush skin with water for at least 15 minutes.
Remove contaminated clothing immediately.
If skin irritation continues, consult a doctor.
After eye contact:
Immediately flush eyes with plenty of water for at least 15 minutes, lifting lower and upper eyelids occasionally. Then consult a doctor.
After swallowing:
Do not induce vomiting, immediately call for medical help.

Fire-fighting measures

· Suitable extinguishing agents: Use fire extinguishing methods suitable to surrounding conditions.
· For safety reasons unsuitable extinguishing agents: Water with full jet.
· Special hazards arising from the substance or mixture: Metal oxide fume.
· Protective equipment: Wear personal protective equipment. Wear respiratory protective device.
· Additional information
Dispose of fire debris and contaminated fire fighting water in accordance with official regulations.
Collect contaminated fire fighting water separately. It must not enter the sewage system

Accidental release measures

· Personal precautions, protective equipment and emergency procedures
Wear protective clothing. Waer respiratory protective device. Avoid formation of dust.
· Environmental precautions:
Do not allow to enter sewers / surface or ground water.
· Methods and material for containment and cleaning up:
Sweep the spill area; avoid raising dust.
Vacuuming or wet sweeping may be used to avoid dust dispersal

Handling and storage

Precautions for safe handling
Prevent formation of dust.
Keep receptacles tightly sealed.
Provide suction extractors if dust is formed.
Use appropriate industrial vacuum cleaners or central vacuum systems for dust removal.
Prevent static electric sparks.
· Information about fire - and explosion protection:
Protect against electrostatic charges.
The product is not flammable.
· Conditions for safe storage, including any incompatibilities
· Storage:
· Requirements to be met by storerooms and receptacles: No special requirements.
· Information about storage in one common storage facility: Store away from foodstuffs und water.
· Further information about storage conditions:
Store in dry conditions.
Store in dry conditions.
This product is hygroscopic.
· Specific end use(s) No further relevant information available.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
None
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
None
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
None
Shipping information
Proper shipping name and description:
None
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
None
Shipping information
Proper shipping name and description:
None
Remarksopen allclose all

Additional transport information

Additional information
Special provisions / remarks / other:
Not dangerous according to the above specifications.
GRACE recommendation for air transport: Cargo aircraft only.

Exposure controls / personal protection

· Personal protective equipment:
· General protective and hygienic measures:
The usual precautionary measures are to be adhered to when handling chemicals.
· Respiratory protection:
If the WEL value is exceeded.
Filter P2
· Protection of hands:
Wear gloves for protection against mechanical hazards according to EN 388.
Use gloves of stable material (e.g. Nitrile) - if necessary tricoted to improve the wearability.
After use of gloves apply skin-cleaning agents and skin cosmetics.
Protective gloves.
Check the condition of the gloves prior to each use.
Check the permeability prior to each anew use of the glove.
The glove material has to be impermeable and resistant to the product/ the substance/ the
preparation.
Preventive skin protection by use of skin-protecting agents is recommended.
· Material of gloves
EN 388: Minimum requirements for efficiency level 1 for all groups.
Butyl rubber, BR
Nitrile rubber, NBR
Recommended thickness of the material: >= 0.11 mm
The selection of the suitable gloves does not only depend on the material, but also on further marks
of quality and varies from manufacturer to manufacturer. As the product is a preparation of several
substances, the resistance of the glove material can not be calculated in advance and has therefore
to be checked prior to the application.
· Penetration time of glove material
The exact break through time has to be obtained from the manufacturer of the protective gloves and
has to be observed.
For the mixture of chemicals mentioned below the penetration time has to be at least 480 minutes
(Permeation according to EN 374 Part 3: Level 6).
EN 420: Minimum requirements for efficiency level 1 for all groups.
· For the permanent contact in work areas without heightened risk of injury (e.g. Laboratory)
gloves made of the following material are suitable:
Butyl rubber, BR
Nitrile rubber, NBR
· For the permanent contact gloves made of the following materials are suitable:
Butyl rubber, BR
Nitrile rubber, NBR
· Not suitable are gloves made of the following materials: cloth gloves
· Eye protection:
Safety glasses, tightly sealed
· Body protection: Protective work clothing.

Stability and reactivity

· Reactivity No further relevant information available.
· Chemical stability No decomposition if used according to specifications.
· Possibility of hazardous reactions: Reacts with strong acids.
· Conditions to avoid No further relevant information available.
· Incompatible materials: No further relevant information available.
· Hazardous decomposition products: Metal oxide smoke

Disposal considerations

Waste treatment methods
· Recommendation: Disposal must be made according to official regulations.