Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the melting point is above 300°C
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-03-01 to 2016-05-18
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
GLP compliance:
yes (incl. QA statement)
Type of method:
differential scanning calorimetry
Key result
Melting / freezing pt.:
> 500 °C
Remarks on result:
other: No melting point could be determined via DSC (differential scanning calorimetry) up to a temperature of 520°C.
Remarks:
The test item changed the colour from white to grey in the pre-test.
Conclusions:
No melting point could be determined via DSC (differential scanning calorimetry) up to a temperature of 520°C.
Therefore the melting point should be stated as > 500°C.

Data source

Materials and methods

Results and discussion