Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
no
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: MG-12/2014
Test procedure:
burning time over 250 mm for metal powders or metal alloys
Burning time:
2 min
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Safety Pre-Test

A small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed. The test item showed no signs of ignition.

Preliminary screening test

The test item was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes.

Interpretation of results:
not classified based on GHS criteria
Conclusions:
FAT 40069/D should be considered as not highly flammable.
Executive summary:

A study was performed to determine the flammability of FAT 40069/D according to EU Method A.10 (Flammability (Solids).

Safety Pre-Test:

A small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed. The test item showed no signs of ignition.

Preliminary screening test:

The test item was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes.

No ignition was observed throughout the course of the test. Hence, the test item FAT 40069/D should be considered as not highly flammable.

Description of key information

A study was performed according to EU Method A.10 (Flammability (Solids). No ignition was observed throughout the course of the test. Hence, the test item FAT 40069/D should be considered as not highly flammable.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

Justification for classification or non-classification

No ignition was observed throughout the course of the test. Hence, FAT 40069/D should be considered as not highly flammable and no classification is required as per the Regulation (EC) No. 1272/2008.