Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosiveness, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From December 4, 2015 to February 19, 2016
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Value:
6
Number of fragments:
0
Remarks on result:
not thermal sensitive if heated under defined confinement
Parameter:
sensitiveness to impact: impact energy (J)
Value:
40
Number of fragments:
0
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Parameter:
sensitiveness to friction: friction load (N)
Value:
360
Number of fragments:
0
Remarks on result:
not sensitive to friction using a friction load of 360 N

Table 1. Thermal sensitivity test

Serials

Mass of sample

(g)

Diameter of orifice

(mm)

Fragment effect of tubes

Test results

1

21.44

6.0

O

No explosion

2

20.91

6.0

O

No explosion

3

21.19

6.0

O

No explosion

4

21.30

2.0

D

No explosion

5

21.13

2.0

D

No explosion

6

21.16

2.0

D

No explosion

O: Tube unchanged

D: Wall of tube split

 

Table 2. Shock sensitivity test

Serials

Drop weight

(kg)

Drop height

(cm)

Impact energy

(J)

Test results

1

10

40

40

No reaction

2

10

40

40

No reaction

3

10

40

40

No reaction

4

10

40

40

No reaction

5

10

40

40

No reaction

6

10

40

40

No reaction

Table 3. Friction sensitivity test

Serials

Weight number

Notch number

Friction load/N

Test results

1

9

VI

360

No reaction

2

9

VI

360

No reaction

3

9

VI

360

No reaction

4

9

VI

360

No reaction

5

9

VI

360

No reaction

6

9

VI

360

No reaction

Interpretation of results:
GHS criteria not met
Conclusions:
According to EU A.14 test method, CJ301 was not considered to present a danger of explosion.
Executive summary:

The explosive properties of CJ301 was determined according to EC REGULATION No 440/2008 Annex A.14 explosive properties. CJ301 does not present a danger of explosioninthe thermal sensitivity (effect of a flame) test and mechanical sensitivity (shock and friction) test. Therefore, CJ301 was not considered to present a danger of explosion.

Description of key information

CJ301 was not considered to present a danger of explosion (EC A.14).

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

CJ301 does not present a danger of explosioninthe thermal sensitivity (effect of a flame) test and mechanical sensitivity (shock and friction) test. Therefore,CJ301 was not considered to present a danger of explosion.

Justification for classification or non-classification