Link to relevant study record(s)

Reference
Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC estimation method
Media:
other: HPLC-column
Specific details on test material used for the study:
Name: FAT 40045/Z
Batch number: AT-2486840
EAS Test item code: 2014-000185
Appearance / colour: solid / dark blue
CAS number 68967-01-1
Purity nominal: >90 % w/w
Molecular weight: 1191.02 g/mol (base), 1271.17 g/mol (salt)
Date of analysis 04 Oct 2013
Expiry date 03 Jul 2018
Storage conditions: cool (+1 to +10 °C}, dark, dry
Radiolabelling:
no
Test temperature:
25 °C
Details on study design: HPLC method:
HPLC-system:
Agilent Technologies 1260 Infinity
Quaternary pump G1311B
Autosampler ALS G1367E
Column oven G1316A
Detector DAD G4212B

Column specification: EC 150/4.6 Nucleodur 100-5 CN-RP 150 x 5
Column temperature: 25 °C
Detection wavelength standard solutions: 220 nm
Detection wavelength test item: 220 nm
Mobile phase: Methanol/water (55/45 ,v/v)
Flow rate: 0.5 mL/min
Injection volume: 2 µL (reference items); 2 µL (test item)
Analytical monitoring:
not specified
Details on sampling:
No data
Type:
log Koc
Value:
< 1.5 dimensionless
Temp.:
25 °C
Details on results (HPLC method):
The aim of this study was the determination of the adsorption coefficient of the test item FAT 40045/Z by high performance liquid chromatography (HPLC) method according to EC method C.19 and OECD guideline 121. The analysis was performed on an analytical column packed with a commercially available cyanopropyl solid phase containing lipophilic and polar moieties. A moderately polar stationary phase based on a silica matrix was used (Nucleodur 100-5 CN-RP). A 55/45 (v/v) methanol water mixture was used as mobile phase and the column temperature was 25 °C. FAT 40045/Z eluted with a retention time of 1.77 min. Since this retention time is lower than the determined dead time of the HPLC, the adsorption coefficient could not be calculated and is therefore below the determination limit of the method (<1.5).
Validity criteria fulfilled:
yes
Conclusions:
Based on the findings of the study, the mean Log Koc of FAT 40045/Z was found to be less than 1.5.
Executive summary:

The aim of this study was the determination of the adsorption coefficient of the test item FAT 40045/Z by high performance liquid chromatography (HPLC) method according to EC method C.19 and OECD guideline 121. The analysis was performed on an analytical column packed with a commercially available cyanopropyl solid phase containing lipophilic and polar moieties. A moderately polar stationary phase based on a silica matrix was used (Nucleodur 100-5 CN-RP). A 55/45 (v/v) methanol water mixture was used as mobile phase and the column temperature was 25 °C. FAT 40045/Z TE eluted with a retention time of 1.77 min. The results are listed below:


 


















Peak No.



Mean retention time of two runs


[min]



Absolute deviation


[min]



Mean log Kocof two runs



1



1.77



0.00



< 1.5*



*: below determination limit of the method


 


Based on the findings of the study, the mean Log Koc was found to be less than 1.5.

Description of key information

A study was performed with the aim to determinate of the adsorption coefficient of the test item FAT 40045/Z TE by high performance liquid chromatography (HPLC) method according to EC method C.19 and OECD guideline 121.The analysis was performed on an analytical column packed with a commercially available cyanopropyl solid phase containing lipophilic and polar moieties. A moderately polar stationary phase based on a silica matrix was used (Nucleodur 100-5 CN-RP).A 55/45 (v/v) methanol/water-mixture was used as mobile phaseand the column temperature was 25 °C. Based on the elution profile the adsorption coefficient (log Koc) was found to be <1.5 at 25 °C.

Key value for chemical safety assessment

Koc at 20 °C:
31.6

Additional information