Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Endpoint:
density
Remarks:
density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Study well documented, meets generally accepted scientific principles, acceptable for assessment.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report date:
2014

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
not specified
GLP compliance:
no
Type of method:
pycnometer method

Test material

Constituent 1
Chemical structure
Reference substance name:
3,3,4,4,5,5,6,6-octafluoro-6-iodohex-1-ene
EC Number:
941-221-0
Cas Number:
203929-12-8
Molecular formula:
C6H3F8I
IUPAC Name:
3,3,4,4,5,5,6,6-octafluoro-6-iodohex-1-ene
Test material form:
not specified
Details on test material:
- Name of test material (as cited in study report): Iodoctafluorhexen (IOFH)

Results and discussion

Density
Type:
density
Density:
1.916 g/cm³
Temp.:
20 °C

Any other information on results incl. tables

Two measurements:

Pycnometer volume at 20°C (V)

10.278 g

Pycnometer weight (m0)

16.5805 g

Pycnometer + sample test 1 at 20°C (m2)

36.2784 g

Pycnometer + sample test 2 at 20°C (m2)

36.268 g

Density test 1 = (m2-m0)/V

1.9165 g/mL

Density test 2 = (m2-m0)/V

1.9155 g/mL

Average

1.916 g/mL

Applicant's summary and conclusion

Conclusions:
The density of IOFH at 20 °C is 1.916 g/cm3.
Executive summary:

The density was measured at 20 °C using a 10 mL pycnometer. Two measurements were done and the result is the arithmetic mean of the two values. No guideline was followed, but the study was well documented and meets generally accepted principles. Therefore, the study is considered acceptable with restrictions.