Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014-02-18 to 2014-07-02
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Dynamic viscosity of test material:
32.7 mPa*s at 20°C
Key result
Flash point:
188 °C
Atm. press.:
1 013 hPa

  Flash point at atmospheric pressure [°C] 

Flash point, corrected to a pressure of 1013 hPa [°C] 

 Preliminary test  190  190
 First run

 187

 187

 Second run

 189

 189

 Mean value  

 188

Interpretation of results:
GHS criteria not met
Conclusions:
Flash point (1013 hPa): 188 °C
Executive summary:

The flash point of the test item was determined according to EU test method A.9 [Council Regulation (EC) No 440/2008, Official Journal L 142/1 2008] with the Pensky-Martens method (closed cup).

Description of key information

Flash point (1013 hPa): 188 °C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
188 °C

Additional information