Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Key value for chemical safety assessment

Flash point at 101 325 Pa:
86 °C

Additional information

The at 25°C, the test material is a solid. Hence, formally the flash point is not a requirement for this substance. Since the test substance melts at about 40°C, the test was performed with liquid test material (>=36°C).

In the Klimisch 1 study from Angly (2000), the flash point of CTFEP (purity 91.4%) was determined under GLP according to EU A.9 and DIN EN 22719. The flash point was determined as 86°C. The identity of the impurities was not reported. Even if the impact of the impurities on the flash point is not known the obtained value is still considered to be used for the risk assessment.