Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
06 Jun - 11 Jul 2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

1
Chemical structure
Reference substance name:
(5Z)-5-(2-methylpropylidene)imidazolidine-2,4-dione
EC Number:
700-726-4
Cas Number:
1369499-44-4
Molecular formula:
C7H10N2O2
IUPAC Name:
(5Z)-5-(2-methylpropylidene)imidazolidine-2,4-dione
Test material form:
solid: particulate/powder

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Any other information on results incl. tables

Preliminary test:


At one end of the pile a flame is applied for maximum 2 minutes. lf the pile bums over a distance of 200 mm within 2 minutes, the main test has to be performed. lf there is no ignition of the test item


after 2 minutes of contact with the flame or the pile bums less than 200 mm within 2 minutes, the main test is unnecessary.


 


Main test:


At one end of the pile a flame is applied. After the pile has burned over a distance of 80 mm, the rate of burning is measured over the next 100 mm. The test is performed six times, using a clean


cool plate each time.


 


Apparatus:


• Mould: L x W x H: 250 x 20 x 10 mm


• Non-combustible, non-porous plate


 


 


Individual Results


 


Preliminary test:


The test item could not be ignited with a flame. The test item melted. The performance of the main test was not necessary.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
Due to the burning behaviour the test item has not to be classified as a "readily combustible solid", class 4.1, of the UN transport regulations.