Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25 August 2010 - 26 August 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted to GLP in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup

Test material

Constituent 1
Chemical structure
Reference substance name:
Tetra-C6-10-(even and linear)-alkyl benzene-1,2,4,5-tetracarboxylate
EC Number:
700-623-4
Cas Number:
263750-17-0
Molecular formula:
C34H54O8 - C50H86O8
IUPAC Name:
Tetra-C6-10-(even and linear)-alkyl benzene-1,2,4,5-tetracarboxylate

Results and discussion

Flash point
Flash point:
> 200 °C

Any other information on results incl. tables

No pressure value stated in the study report.

The flash point of the reference substance, Naphthalene was determined to be 80 °C, corresponding to the literature value (80 °C).

In case of the test item three replicate tests were carried out.

Result obtained for the test material: no flash point was observed up to 200 °C.

Applicant's summary and conclusion

Conclusions:
No flash point was observed for the test material up to 200 °C.
Executive summary:

In a flash point study (10/095-352AN), no flash point was observed for the test material up to 200 °C based on EU Test Method A.9.