Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Lack of experimental details Bisphenol-A is one of the main constituents of the reaction mass so that Bisphenol-A hazard data are applied in the hazard assessment.
Principles of method if other than guideline:
other
Type of method:
other: other
Boiling pt.:
>= 250 - <= 252 °C
Atm. press.:
17 hPa
Decomposition:
yes
Executive summary:

The boiling point of Bisphenol A at 17 hPa is 250 - 252°C with potential decomposition.

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Lack of original test data Bisphenol-A is one of the main constituents of the reaction mass so that Bisphenol-A hazard data are applied in the hazard assessment.
Principles of method if other than guideline:
other
Type of method:
other: other
Boiling pt.:
360 °C
Atm. press.:
1 013 hPa
Decomposition:
yes
Executive summary:

The boiling point of Bisphenol A at 1013 hPa is 360 °C with decomposition.

Description of key information

The boiling point of Bisphenol A (with decomposition) is between 250 and 360°C.

Key value for chemical safety assessment

Boiling point at 101 325 Pa:
250 °C

Additional information

The substance mainly consists of phenol and bisphenol-A. It does not have a well-defined boiling point. The test is therefore technically not feasible. The boiling points of phenol and bisphenol-A are provided instead.