Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
February 2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study by a laboratory having a GLP certificate

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Certificate on january 29th 2008
Type of method:
equilibrium method closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flash point
Flash point:
> 140.5
Atm. press.:
99 kPa

Any other information on results incl. tables

Results

Preliminary test

Atmospheric pressure                     About 99.0 kPa

Relative humidity                 About 27% of saturated air

Tested temperature range            Between 80.5 and 140.5 °C (corrected values)

            No flash point was observed up to 140.5 °C (corrected value).

Remark: At 140.5 °C, only a blue halo was observed which is not considered as a flash point. Then, the test was performed at 150.5 °C (corrected value), but the test item solidified and the aluminium cup was damaged. The test was stopped.

            The test was considered to be not applicable for this test item.

No main test was performed.

Conclusion

            No flash point was observed up to 140.5 °C (corrected value).

Applicant's summary and conclusion