Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study
Qualifier:
according to guideline
Guideline:
other: Standard Operating Procedure SPR/BC-FC/08/b “Flammability solids”
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Burning time:
ca. 550 s
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Results

Preliminary stage I of determination

 

Test number

Time of ignition [s]

Comments

Test-1

30

After applying a flame from a gas burner to the sample it ignites at ones. After taking off the burner of the sample it flame, then glowing and emission of small amount of smokes.

Test-2

20

Test-3

60

 

Positive results, it is necessary to go to the next stage of determination.

 

Stage II of determination -Burning time on the zone of path or roller

 

Test number

Burning time [s]

Comments

Test-1

516

The path combustion is complete

Test-2

545

Test-3

590

 

Negative results, burning times of the path longer than 4 minutes (limiting criterion). It is not necessary to carry out the burning rate determination.

 

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
The test item was not flammable under the conditions of the test.
Executive summary:

The test substance has been determined to be non flammable in a GLP study (2008) according to the Standard Operating Procedure SPR/BC-FC/08/b “Flammability solids”, which corresponds to EU method A.10.

Description of key information

The test substance has been determined to be non flammable in a GLP study (2008)

according to the Standard Operating Procedure SPR/BC-FC/08/b “Flammability solids”, which corresponds to EU method A.10.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

Justification for classification or non-classification

The test material does not meet the criteria for classification and will not require labelling in accordance with European Regulation (EC) No. 1272/2008, amending Regulation EC No. 1907/2006 (REACH).