Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
GLP compliance:
yes (incl. QA statement)
Type of method:
thermal analysis
Remarks:
Differential Scanning Calorimetry

Test material

Constituent 1
Chemical structure
Reference substance name:
1-ethyl-3-methyl-1H-imidazol-3-ium methanesulfonate
EC Number:
604-453-0
Cas Number:
145022-45-3
Molecular formula:
C6 H11 N2. C H3 O3 S
IUPAC Name:
1-ethyl-3-methyl-1H-imidazol-3-ium methanesulfonate
Details on test material:
Name of test material (as cited in study report): EMIM Methansulfonat
Analytical purity: 99.6 g/100g by 1H-NMR spectroscopy using the internal standard method, molar ratio cation / anion: 49.5 % / 50.5 %
(determined during the GLP-study No. 11L00321 from Competence Center Analytics, BASF SE)
Lot/batch No.: 11-0001

Results and discussion

Melting / freezing pointopen allclose all
Melting / freezing pt.:
16 °C
Atm. press.:
1 013 hPa
Remarks on result:
other: Modification A
Melting / freezing pt.:
33 °C
Atm. press.:
1 013 hPa
Remarks on result:
other: Modification B
Remarks on result:
other: a glass transition is found at -68°C

Any other information on results incl. tables

Results:

Melting temperature (1st heating)

 

Measurement

 

Glass transition [°C]

 

Peak temperature 1st peak [°C]

 

Peak temperature 2nd peak [°C]

G

 -67.5  (16.0)2  (32.4)2
H  -66.7 (17.2)2  (not found)2
 I  -68.0 (17.3)2  (32.4)2
 K  (-68.8)1  15.9  33.3
 L  (-69.4)1  16.2  not found
 mean  -67  16  33

1 Due to the heating rate of 2 K/min not used. 2 Due to the heating rate of 20 K/min not used.

The test item shows crystal modifications. Depending on the crystal modifikation two different melting temperatures were found at 16°C and 33°C.

A glass transitions was found at -67°C in the 1st heating with 20 K/min.

Observed thermic processes:

An exothemic peak at about 0°C peaktemperature shows the recrystallization of the test item.

The estimated accuracy is +/- 1°C.