Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
appearance / physical state / colour
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
GLP compliance:
not specified
Specific details on test material used for the study:
Lot: #210162718
Physical state at 20°C and 1013 hPa:
liquid
Key result
Form:
liquid: viscous
Colour:
yellowish
Odour:
other: mild
Substance type:
other: UVCB
Conclusions:
Under the study conditions, the test substance was a yellowish viscous liquid with a mild odour.
Executive summary:

A study was conducted to determine the appearance, physical state and colour of the test substance. Under the study conditions, the test substance was a yellowish viscous liquid with a mild odour (Sohar, 2015).

Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Principles of method if other than guideline:
Method: DIN EN ISO 2719
GLP compliance:
not specified
Type of method:
closed cup
Remarks:
Pensky-Martens closed cup method
Flash point apparatus:
Setaflash apparatus
Remarks:
Seta multiflash flash point tester from Petrotest, Modul No.34000-0
Specific details on test material used for the study:
Lot: #210162718
Appearance: viscous liquid
Key result
Flash point:
161 °C
Atm. press.:
ca. 101 325 Pa
Conclusions:
Under the study conditions, the flash point of the test substance was 161°C (Pensky-Martens closed cup method).
Executive summary:

A study was conducted to determine the flash point of the test substance according to EU Method A.9 (DIN EN ISO 2719). The flash point was determined by Pensky-Martens closed cup method, using a Setaflash apparatus. Under the study conditions, the flash point of the test substance was 161°C (Sohar, 2015).

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion