First-aid measures

Emergency measure - Inhalation: Remove the casualty to fresh air. Consult physician. Note to physician: Treat symptomatically. After massive exposure control of hemogram every 2-3 days for 2-3 weeks.
Emergency measure - Eyes: Rinse immediately with water for 10 minutes - open eyelids forcibly. Consult physician.
Emergency measure - Skin: Remove immediately contaminated clothes, wash affected skin with water and soap - do not use any solvents.
Emergency measure - Ingestion: Do not induce vomiting. Call a physician and/or transport to emergency facility immediately. Note to physician: decision to induce vomiting or not if large volumes have been ingested should be made by an attending physician. Supportive care should be based on
judgement of the physician in response to the reaction of the patient.

Fire-fighting measures

Recommended extinguishing agent: Suitable extinguishing media: water spray jet, dry powder, foam, carbon dioxide.
Specific hazards: formation of toxic and corrosive combustion gases (hydrogen fluoride, nitrous oxides, carbon oxides) possible.
Protection of fire-fighters: precipitate gases/vapours/ mists with water spray - use self-contained breathing apparatus.
Special method of fire-fighting: cool endangered containers with water spray.
Product arising from burning: Oxides of carbon, nitrogen and fluorine expected.
Product determined by test: N

Accidental release measures

Emergency measures in case of spillage: Personal precautions: keep people away and stay on the upwind side.
Environmental protection : avoid release to the environment.
Methods for cleaning up: collect solids (avoid dust formation) and place in a suitable container for disposal by a licensed waste disposal firm.

Handling and storage

HANDLING AND STORAGE
Risk Management Measures: This substance is handled under Strictly Controlled Conditions in accordance with REACH Regulation Article 18(4) for transported intermediates and ECHA Guidance on Intermediates, version 2-December 2010 (Reference: ECHA-2010-G-17-EN). The substance is used only in one site in the EU. Site documentation to support safe handling arrangements including the selection of engineering, administrative and personal protective equipment controls in accordance with risk-based management systems is available at the use site.

Handling:
Technical measures:
- processing in closed systems superposed by inert gas (e.g. nitrogen),
- local exhaust ventilation necessary,
- taken precautionary measured against electrostatic charging,
- avoid dust formation consider dust explosion hazard.

Suitable materials: stainless steel, glass, enamel, polyethylene.

Storage:
Storage validity: 24 months at room temperature.

Packaging materials: store in polythene bags in tightly closed containers of mild steel, coated mild steel, high density polyethylene or fibreboard.

Packaging of the substance and or preparation: Double packed in polythene bags of 20 kg or less inside a fibreboard keg or steel drum.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: Substance not classified by transport regulations.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

EXPOSURE CONTROLS / PERSONAL PROTECTION
Risk Management Measures: This substance is handled under Strictly Controlled Conditions in accordance with REACH Regulation Article 18(4) for transported intermediates and ECHA Guidance on Intermediates, version 2-December 2010 (Reference: ECHA-2010-G-17-EN). The substance is used only in one site in the EU. Site documentation to support safe handling arrangements including the selection of engineering, administrative and personal protective equipment controls in accordance with risk-based management systems is available at the use site

Stability and reactivity

Danger other than fire: Avoid contact with strong acids, bases and strongly oxidising materials.

Chemical reaction with water: No undue reaction expected in combination with water.

Dust explosion: The minimum ignition energy of the substance was determined in a cylindrical vessel using a variable capacitance spark
discharge circuit. Tests were conducted in accordance with ASTM E2019, "Standard Test Method for Minimum Ignition Energy of a Dust Cloud in Air". The minimum ignition energy (MIE) is the lowest energy (of an electrostatic spark) at which a deflagration was observable. On the basis of the
tests conducted, tested as received material, the substance has the following MIE:
MIE = 25.5 mJ

The reported MIE value includes the 5 mJ energy associated with the spark gap ionization circuit.

Moisture content testing on the substance was performed prior to testing in the 20 liter vessel. Based on this testing, the moisture content was determined to be 3.0% by weight.

FIKE Corporation Report No. 10427082Rev1.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: None, the substance is expected to be fully consumed in the process described above. Accidental spills during the charging of the reactor will be immediately collected and charged to the reactor.

There is no practical recovery or recycling option.

Industry - Possibility of neutralisation: None anticipated.

Industry - Possibility of destruction: controlled discharge: Not relevant.

Industry - Possibility of destruction - incineration: Process waste collected and disposed of by a licensed professional waste disposal contractor for off-site incineration or treatment - depending on testing results.

Industry - Possibility of destruction - water purification: Not relevant.

Industry - Possibility of destruction - other: Not relevant.

Public at large - Possibility of recovery/recycling: Not applicable; the substance is not meant for the public at large.

Public at large - Possibility of neutralisation: Not applicable; the substance is not meant for the public at large.

Public at large - Possibility of destruction: controlled discharge: Not applicable; the substance is not meant for the public at large.

Public at large - Possibility of destruction - incineration: Not applicable; the substance is not meant for the public at large.

Public at large - Possibility of destruction - water purification: Not applicable; the substance is not meant for the public at large.

Public at large - Possibility of destruction - others: Not applicable; the substance is not meant for the public at large.