First-aid measures

Emergency measure - Inhalation: Move to fresh air. If you feel unwell, seek medical

advice. Remove patient from danger zone. In case of

breathing difficulties rush to hospital.

Emergency measure - Eyes: Rinse immediately with gently running water for 15

minutes, maintaining eyelids open. Consult an

ophthalmologist or a physician.

Emergency measure - Skin: Rinse skin immediately with copious amounts of water.

Immediately remove contaminated clothing. Consult a

physician if any symptoms develop.

Emergency measure - Ingestion: If swallowed, seek medical advice immediately and show this

container or label.

Fire-fighting measures

Recommended extinguishing agent: Water spray, foam, dry powder or carbon dioxide.

Product arising from burning: Carbon oxides, nitrogen oxides.

Product determined by test: N

Protective equipment: Fire fighters should wear appropriate protective equipment

and self-contained breathing apparatus with a full face-

piece operated in positive pressure mode. Fight fire in

early stages if safe to do so. Containers at risk from fire

should be cooled with water and, if possible, removed from

the danger area. Do not let enter contaminated extinguishing

water into the soil, groundwater or surface waters.

Accidental release measures

Emergency measures in case of spillage: Take up avoiding formation of dust. Fill into labelled,

sealable containers. Ensure adequate ventilation/exhaust

ventilation. Keep unauthorized persons away. Use the

necessary personal protective equipment when handling.

Handling and storage

Handling: When handling the usual precautionary measures for chemicals

have to be observed. Avoid contact with skin, eyes and the

inhalation of dust. When exposure cannot be prevented

adequately controlled, appropriate personal protection

equipment should be worn, i.e. protective clothing,

chemical-resistant gloves and goggles. After contamination

with product change the gloves immediately and remove them

according to relevant national and local regulations. In

case of dust formation wear respiratory protection:

combination filter against organic vapours and particles,

e.g. DIN 3181 ABEK-P2. Ensure effective ventilation. Vent

waste air via suitable separators or scrubbers. Wash hands

before breaks and end of work. Keep work clothes separate.

Keep away form sources of ignition. Precautions should

generally be taken against electrostatic charges according

to the equipment used and the way the product is handled and

packaged.

Storage: Store sealed in original container in a cool, dry place.

Protect form moisture. Keep storage area clean and well

ventilated. Vent waste air via suitable seperators or

scrubbers. Storerooms are to be maintained according to the

principles of a good industrial hygiene. Containers that

have been opened are to be tightly closed after use. Avoid

contamination of containers with the product. Keep away from

sources of ignition. Precautions should generally be taken

against electrostatic charges according to the equipment

used and the way the product is handled and packaged. Do not

let enter contaminated water into soil, groundwater or

surface waters.

Packaging of the substance and or preparation: Kegs with PE-inliner (20-25 kg).

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport code: no restriction
Transport: Transport condition follows the transport code classified.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: No thermal decomposition and no hazardous decomposition

products when stored and handled correctly.

Chemical reaction with water: None known.

Dust explosion: Positive.

Dust explosion determined by test: Y

Disposal considerations

Industry - Possibility of recovery/recycling: not applicable.

Industry - Possibility of neutralisation: not applicable.

Industry - Possibility of destruction: controlled discharge: not recommended.

Industry - Possibility of destruction - incineration: Dispose at a suitable waste incineration plant in accordance

with the official regulations.

Industry - Possibility of destruction - water purification: Not applicable.

Public at large - Possibility of recovery/recycling: The substance is an intermediate for industrial use only and

will not occur in public at large.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: not applicable.

Public at large - Possibility of destruction - incineration: not applicable.

Public at large - Possibility of destruction - water purification: not applicable.

Public at large - Possibility of destruction - others: not applicable.