Administrative data

First-aid measures

Emergency measure - Inhalation: If swallowed, seek medical advice immediately and show this
container or label.
Emergency measure - Eyes: Rinse eyes thoroughly with running water (approximately 15
minutes) and consult a physician if any symptoms persist.
Emergency measure - Skin: Take off all contaminanted clothing immediately. After
contact with skin, wash immediately with plenty of water and
soap.
Emergency measure - Ingestion: Move to fresh air. If you feel unwell, seek medical advice.

Fire-fighting measures

Recommended extinguishing agent: water, foam, CO2

Product arising from burning: carbon monoxide, hydrogen chloride

Product determined by test: N

Protective equipment: The on-site fire crews would tackle any localized fire with
a dry powder extinguisher. If a major fire is involved, the
building sprinkler system would automatically activate. The
process drainage system is arranged such that all process
effluent is captured within a catchment pit which prevents
transfer to the site effluent treatment plant (ETP). As
required, the contents of this pit can be transferred to a
holding tank for subsequent analysis and despatch for
incineration. If there is a risk of fume inhalation, the
firemen would wear breathing apparatus and fire-fighting
PPE.

Accidental release measures

Emergency measures in case of spillage: In the event of spillage, the solid material will be
collected in dry form, sealed in a lined drum, labelled and
incinerated. The subsequent water washings are isolated,
analysed and treated in the waste treatment unit or
incinerated depending on concentration.


Liquid spillages would be isolated in catchment pits within
the manufacturing area.

Handling and storage

Handling: Engineering:

Local exhaust ventilation with HEPA filtration

PPE:

Operators to wear;

Nitrile gloves in line with EN 388 and EN 374

Chemical protective suit in line with EN 465

Protective footwear to EN345

Safety glasses in line with EN1661

Air-fed hood tested in line with EN141-3, wherever there is
danger from open plant i.e. risk of exposure to an oxygen-
deficient atmosphere (ODA). If there is no danger from an
ODA, use a Tornado powered respirator with filter tested in
line with EN141-3

Storage: The enclosed substance, suitably labelled, will be stored
under cover in a warehouse unit at ambient temperature until
required for use in the production building. Only the
required amount for one batch will be transferred to the
production building at any one time.

Packaging of the substance and or preparation: The solid will be delivered in fibre-board kegs within
polythene liners, 50 kg nett.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport code: RID/ADR: not restricted
Transport: Fork lift or hand lift trucks on pallet.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: none known.

Chemical reaction with water: none known.

Dust explosion: not known.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: There is no provision for recovery of any materials from the
process.

Industry - Possibility of neutralisation: It is not anticipated that this will apply. Any unwanted
material would be incinerated at a licensed incineration
facility in the UK.

Industry - Possibility of destruction: controlled discharge: As described above, all process effluent will be contained,
prevented from entering the environment and will be sent for
incineration.

Industry - Possibility of destruction - incineration: As described above, all process effluent will be contained,
prevented from entering the environment and will be sent for
incineration.

Industry - Possibility of destruction - water purification: not applicable.

Public at large - Possibility of recovery/recycling: not applicable.

Public at large - Possibility of neutralisation: not applicable.

Public at large - Possibility of destruction: controlled discharge: not applicable.

Public at large - Possibility of destruction - incineration: not applicable.

Public at large - Possibility of destruction - water purification: not applicable.

Public at large - Possibility of destruction - others: not applicable.